On 1/14/26 1:14 PM, Sascha Hauer wrote:
> Fix the linker script to generate three distinct PT_LOAD segments with
> correct permissions instead of combining .rodata with .data.
>
> Before this fix, the linker auto-generated only two PT_LOAD segments:
> 1. Text segment (PF_R|PF_X)
> 2. Data segment (PF_R|PF_W) - containing .rodata, .data, .bss, etc.
>
> With explicit PHDRS directives, we now generate three segments:
> 1. text segment (PF_R|PF_X): .text and related code sections
> 2. rodata segment (PF_R): .rodata and related read-only sections
> 3. data segment (PF_R|PF_W): .data, .bss, and related sections
>
> With this we can setup the MMU properly from outside the ELF binary.
>
> Signed-off-by: Sascha Hauer <[email protected]>
Reviewed-by: Ahmad Fatoum <[email protected]>
> ---
> arch/riscv/lib/barebox.lds.S | 38 +++++++++++++++++++++++++-------------
> 1 file changed, 25 insertions(+), 13 deletions(-)
>
> diff --git a/arch/riscv/lib/barebox.lds.S b/arch/riscv/lib/barebox.lds.S
> index
> 03b3a967193cfee1c67b96632cf972a553e8bec4..0cfa4bff57920bfaed822cb62c553c49f543994c
> 100644
> --- a/arch/riscv/lib/barebox.lds.S
> +++ b/arch/riscv/lib/barebox.lds.S
> @@ -16,14 +16,23 @@
> OUTPUT_ARCH(BAREBOX_OUTPUT_ARCH)
> ENTRY(start)
> OUTPUT_FORMAT(BAREBOX_OUTPUT_FORMAT)
> +
> +PHDRS
> +{
> + text PT_LOAD FLAGS(5); /* PF_R | PF_X */
> + rodata PT_LOAD FLAGS(4); /* PF_R */
> + dynamic PT_DYNAMIC FLAGS(4); /* PF_R */
> + data PT_LOAD FLAGS(6); /* PF_R | PF_W */
> +}
> +
> SECTIONS
> {
> . = 0x0;
>
> - .image_start : { *(.__image_start) }
> + .image_start : { *(.__image_start) } :text
>
> . = ALIGN(4);
> - ._text : { *(._text) }
> + ._text : { *(._text) } :text
> .text :
> {
> _stext = .;
> @@ -35,44 +44,47 @@ SECTIONS
> KEEP(*(.text_exceptions*))
> __exceptions_stop = .;
> *(.text*)
> - }
> + } :text
> BAREBOX_BARE_INIT_SIZE
>
> - . = ALIGN(4);
> + . = ALIGN(4096);
> __start_rodata = .;
> .rodata : {
> *(.rodata*)
> RO_DATA_SECTION
> - }
> + } :rodata
> +
> + .dynamic : { *(.dynamic) } :rodata :dynamic
>
> __end_rodata = .;
> _etext = .;
> _sdata = .;
>
> - . = ALIGN(4);
> - .data : { *(.data*) }
> + . = ALIGN(4096);
> +
> + .data : { *(.data*) } :data
>
> /DISCARD/ : { *(.rela.plt*) }
> .rela.dyn : {
> __rel_dyn_start = .;
> *(.rel*)
> __rel_dyn_end = .;
> - }
> + } :data
>
> .dynsym : {
> __dynsym_start = .;
> *(.dynsym)
> __dynsym_end = .;
> - }
> + } :data
>
> _edata = .;
>
> - .image_end : { *(.__image_end) }
> + .image_end : { *(.__image_end) } :data
>
> . = ALIGN(4);
> - .__bss_start : { *(.__bss_start) }
> - .bss : { *(.bss*) }
> - .__bss_stop : { *(.__bss_stop) }
> + .__bss_start : { *(.__bss_start) } :data
> + .bss : { *(.bss*) } :data
> + .__bss_stop : { *(.__bss_stop) } :data
> _end = .;
> _barebox_image_size = __bss_start;
> }
>
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |