On 1/14/26 1:14 PM, Sascha Hauer wrote:
> Fix the linker script to generate three distinct PT_LOAD segments with
> correct permissions instead of combining .rodata with .data.
> 
> Before this fix, the linker auto-generated only two PT_LOAD segments:
> 1. Text segment (PF_R|PF_X)
> 2. Data segment (PF_R|PF_W) - containing .rodata, .data, .bss, etc.
> 
> With explicit PHDRS directives, we now generate three segments:
> 1. text segment (PF_R|PF_X): .text and related code sections
> 2. rodata segment (PF_R): .rodata and related read-only sections
> 3. data segment (PF_R|PF_W): .data, .bss, and related sections
> 
> With this we can setup the MMU properly from outside the ELF binary.
> 
> Signed-off-by: Sascha Hauer <[email protected]>

Reviewed-by: Ahmad Fatoum <[email protected]>

> ---
>  arch/riscv/lib/barebox.lds.S | 38 +++++++++++++++++++++++++-------------
>  1 file changed, 25 insertions(+), 13 deletions(-)
> 
> diff --git a/arch/riscv/lib/barebox.lds.S b/arch/riscv/lib/barebox.lds.S
> index 
> 03b3a967193cfee1c67b96632cf972a553e8bec4..0cfa4bff57920bfaed822cb62c553c49f543994c
>  100644
> --- a/arch/riscv/lib/barebox.lds.S
> +++ b/arch/riscv/lib/barebox.lds.S
> @@ -16,14 +16,23 @@
>  OUTPUT_ARCH(BAREBOX_OUTPUT_ARCH)
>  ENTRY(start)
>  OUTPUT_FORMAT(BAREBOX_OUTPUT_FORMAT)
> +
> +PHDRS
> +{
> +     text PT_LOAD FLAGS(5);          /* PF_R | PF_X */
> +     rodata PT_LOAD FLAGS(4);        /* PF_R */
> +     dynamic PT_DYNAMIC FLAGS(4);    /* PF_R */
> +     data PT_LOAD FLAGS(6);          /* PF_R | PF_W */
> +}
> +
>  SECTIONS
>  {
>       . = 0x0;
>  
> -     .image_start : { *(.__image_start) }
> +     .image_start : { *(.__image_start) } :text
>  
>       . = ALIGN(4);
> -     ._text : { *(._text) }
> +     ._text : { *(._text) } :text
>       .text      :
>       {
>               _stext = .;
> @@ -35,44 +44,47 @@ SECTIONS
>               KEEP(*(.text_exceptions*))
>               __exceptions_stop = .;
>               *(.text*)
> -     }
> +     } :text
>       BAREBOX_BARE_INIT_SIZE
>  
> -     . = ALIGN(4);
> +     . = ALIGN(4096);
>       __start_rodata = .;
>       .rodata : {
>               *(.rodata*)
>               RO_DATA_SECTION
> -     }
> +     } :rodata
> +
> +     .dynamic : { *(.dynamic) } :rodata :dynamic
>  
>       __end_rodata = .;
>       _etext = .;
>       _sdata = .;
>  
> -     . = ALIGN(4);
> -     .data : { *(.data*) }
> +     . = ALIGN(4096);
> +
> +     .data : { *(.data*) } :data
>  
>       /DISCARD/ : { *(.rela.plt*) }
>       .rela.dyn : {
>               __rel_dyn_start = .;
>               *(.rel*)
>               __rel_dyn_end = .;
> -     }
> +     } :data
>  
>       .dynsym : {
>               __dynsym_start = .;
>               *(.dynsym)
>               __dynsym_end = .;
> -     }
> +     } :data
>  
>       _edata = .;
>  
> -     .image_end : { *(.__image_end) }
> +     .image_end : { *(.__image_end) } :data
>  
>       . = ALIGN(4);
> -     .__bss_start :  { *(.__bss_start) }
> -     .bss : { *(.bss*) }
> -     .__bss_stop :  { *(.__bss_stop) }
> +     .__bss_start :  { *(.__bss_start) } :data
> +     .bss : { *(.bss*) } :data
> +     .__bss_stop :  { *(.__bss_stop) } :data
>       _end = .;
>       _barebox_image_size = __bss_start;
>  }
> 

-- 
Pengutronix e.K.                  |                             |
Steuerwalder Str. 21              | http://www.pengutronix.de/  |
31137 Hildesheim, Germany         | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686  | Fax:   +49-5121-206917-5555 |


Reply via email to