On Thu, 29 Jan 2026 12:35:05 +0100, Sascha Hauer wrote:
> The fixed regulator has a "off-on-delay-us" property which we wrongly
> interpret as delay needed until a regulator has been fully ramped up
> and a "startup-delay-us" which exists for that purpose, but we didn't
> handle at all. This series fixes this.
> 
> 

Applied, thanks!

[1/2] regulator: fix handling of off_on_delay
      https://git.pengutronix.de/cgit/barebox/commit/?id=f7f6f176afbc (link may 
not be stable)
[2/2] regulator: fixed: handle startup-delay-us property
      https://git.pengutronix.de/cgit/barebox/commit/?id=7397e0536982 (link may 
not be stable)

Best regards,
-- 
Sascha Hauer <[email protected]>