HI All, 

I'm trying to trouble shoot why my two HIH4001 (or 4003) humidity sensors 
died after a couple of days of being connected to the beagle bone in my 
current config.

I've got one connected to AIN5 and the other to 6 (central pin -- output 
voltage),   via voltage dividers to knock the voltage down below 1.8 V. 

Output pins are tied to ground via 80K resistors (pulldown).
Ground runs to BBB ground, and is also tied to AGND.


Power is supplied via  SYS_5v --- I thought this would give me a regulated 
supply. The measurements with a multimeter look good.


After a couple of days the sensors were providing constant 2.6 V as output 
and are unresponsive.

Can anyone see anything I am doing wrong with this setup?

Thanks for your help.

Kind regards

Matt

-- 
For more options, visit http://beagleboard.org/discuss
--- 
You received this message because you are subscribed to the Google Groups 
"BeagleBoard" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to beagleboard+unsubscr...@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.

Reply via email to