Thank you Grissiom....

On Tuesday, March 11, 2014 10:19:28 AM UTC+9, Grissiom Gu wrote:
>
> On Mon, Mar 10, 2014 at 11:00 PM, Paddu <pradeep....@gmail.com<javascript:>
> > wrote:
>
>>
>> Hi,
>>
>> Thank you for sharing very useful information.
>> With your suggestions currently I am able to read the Cycle count using 
>> using this register.
>> Please let me ask more question about CCNT register.
>>
>> Just for the confirmation, I would like to know is this a 32 bit 
>> register? or 64 bit?
>> and what would happen if the count value is overflown, will the register 
>> reset to "0" ?
>>
>
> It is a 32bit register(use "mrc" to read it instead of "mrrc"). If you are 
> afraid of overflow and don't want to deal with the interrupt, you could set 
> the D bit in PMCR register(c9, c12, 0). Than PMU will divide the cycle with 
> 64.
>
> -- 
> Cheers,
> Grissiom 
>

-- 