On 2013-03-18 15:50, Mark Andrews wrote:
Named will transfer from the master with the highest serial.  Notify
just triggers early refresh checks.

Does it actually check each master for a serial number, or does it stop at the first one queried if it has a higher-than-current serial number?

I've been meaning to test this in the real world, but if anyone can tell me, it would save a bit of time :)

--
Dave Warren
http://www.hireahit.com/
http://ca.linkedin.com/in/davejwarren