jean-christophe manciot <[email protected]> wrote: > However, if I increment the serial number (SN) on the primary from > 2019101614 to 2019101709 and order a retransfer on the secondary with "rndc > retransfer sdxlive.com", I get in the logs: > *on the primary*: > > (serial 2019101614)
Did you `rndc reload sdxlive.com` on the primary? If the zone file on the primary can be edited by `named` (dynamic updates, signing, etc) then you need to `rndc freeze`, edit, `rndc thaw` instead. Tony. -- f.anthony.n.finch <[email protected]> http://dotat.at/ Hebrides, Bailey: Southeast backing northeast 4 to 6, occasionally 7 in Bailey. Rough or very rough, occasionally moderate later in Hebrides. Showers. Moderate. _______________________________________________ Please visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe from this list bind-users mailing list [email protected] https://lists.isc.org/mailman/listinfo/bind-users