Ray,
 
The Index Basic D may be used with the BrailleNote, but you will need to use 
the serial port and not the USB connection.  The USB port on the Index Basic D 
is not a true USB port and the mPower doesn't have the necessary software to 
handle the Index USB.

The following is an extract from some instructions that I prepared for another 
client for using an mPower with an Index D.

Use the black null modem cable that comes with the BrailleNote for the serial 
cable.  This is important.

Operation of Embosser over Serial Port.

As mentioned at the beginning of this document, if you are wishing to use the 
Index with an mPower BrailleNote you will need to use the Serial cable 
connection.  You may also use the Serial Connection with the Classic 
BrailleNote.  You must also change the BrailleNote's Embosser Setting list to 
match the serial connection settings.   This is described in the next section.

To use the Serial connection you must connect the Embosser using the serial 
cable provided (BrailleNote Null modem cable), which has 9 way female sockets 
at both ends of the cable.

To select the serial communication option on the Embosser, you must take the 
Embosser Off Line, then press the Set-up B button.  This is labelled with the 
letter B.  Return the printer On Line by pressing the On Line button.  The 
Embosser will remember that you have selected Set-up B as the default start up 
configuration and it will start using Set-up B each time the Embosser is 
switched on.  The Embosser sign-on message will also say that Set-up B is 
loaded.

If you wish to return the unit to Parallel port operation, simply take the 
Embosser Off Line, then press Set-up A, and put the Embosser back On Line.

BrailleNote Setting for Serial Port Operation.

Go to the KeyWord Menu, then select Emboss a Document, and the type S to set-up 
the embosser.

Once in the Embosser Set-up List, move through and check that the paper length 
is 29 lines, and that it is indicating that the embosser is set to emboss both 
sides of the page.  At the Embosser Port? prompt type S for Serial.  This will 
then open up all the parameters associated with the serial port.  Check that 
the settings are set to: Baud Rate 9600, Parity None, Number of data bits 8, 
Handshaking Software, then exit the embosser set-up list and press Y to confirm 
your changes.

After these changes have been made any file that you emboss will be printed as 
40 characters per row with 29 lines per page.  If you want to include page 
number, go to the Format Menu, select Layout, and move through the list until 
you locate the item "Emboss Page Numbers".

Regards
 
Maurice Sloane
HumanWare NZ

________________________________

From: [EMAIL PROTECTED] on behalf of Ray Campbell
Sent: Sat 26/07/2008 9:14 a.m.
To: [email protected]
Subject: [Braillenote] Embossing from the BN mPower to the Basic D



Hello All:

I'm working with a student who is running the Braille Note mPower with
Keysoft Version 7.2.  She wants to be able to emboss directly to a Basic
D embosser.

Does HW or anyone else have drivers for the BN mPower that can be
downloaded so you can emboss onto the Basic D?  Does HW have plans to
support the Index embossers, including the Basic D and if so, when?

Thanks,



Ray Campbell, Help Desk Technician
Adaptive Technology Center
Chicago Lighthouse for People Who Are Blind or Visually Impaired
1850 W. Roosevelt Road
Chicago, IL  60608
312-997-3651 (Voice/Relay) or
888-825-0080 (voice/Relay)
[EMAIL PROTECTED]
AIM Screen Name: tclhelp

___
Replies to this message will go directly to the sender.
If your reply would be useful to the list, please send a
copy to the list as well.

To leave the BrailleNote list, send a blank message to
[EMAIL PROTECTED]
To view the list archives or change your preferences, visit
http://list.humanware.com/mailman/listinfo/braillenote



___
Replies to this message will go directly to the sender.