No, I didn't, but, I did have to turn down the water pressure via a
regular to get it into spec.  Have you checked the inlet water
pressure?

Rob

On May 6, 5:36 pm, Sludgemaster <[email protected]> wrote:
> I just finished a rotary conversion due to a vibe pump failure and all
> was well until I adjusted the brew pressure because after the
> conversion the pressue was only at 8.  Upon bringing it up to 9, there
> is a squeeling sound coming from the brew group when I pull a shot.  I
> am wondering if anybody has had a similar experience or knows the
> cause.
>
> Thanks
>
> --
> You received this message because you are subscribed to the Google Groups 
> "Brewtus" group.
> To post to this group, send email to [email protected].
> To unsubscribe from this group, send email to 
> [email protected].
> For more options, visit this group 
> athttp://groups.google.com/group/brewtus?hl=en.

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To post to this group, send email to [email protected].
To unsubscribe from this group, send email to 
[email protected].
For more options, visit this group at 
http://groups.google.com/group/brewtus?hl=en.

Reply via email to