On 1/25/20 4:34 PM, Andrew Lunn wrote:
> Allan mentioned you might get around to implementing 802.1CB?

I read about MRP, being IEC 62439-2, and then I read further about IEC 
62439-3.4 Parallel Redundancy Protocol (PRP).

So is this 802.1CB-2017 - IEEE Standard then the same as PRP? (I mean, out of 
curiosity, why not stay in the same standard, then you pay only once ;-)


Kind regards,

Jürgen

Reply via email to