Christian Severin <[email protected]> writes: > Salvete, > > I try to connect to a Handy Tech Braillino 20 > that is connected to my Windows 7 laptop > by a USB-to-serial cable that ends up as COM4 > by going to brltty-win-4.5-1/bin and entering > > brltty -bht -dserial:COM4 -ldebug -Lbrltty.log > > which, after 60 rows of initializing, gives me > "serial device opened: //./COM4: fh=00000164" > and > "Detected unknown HandyTech model with ID E3." > > I have experimented with using the -dUSB: switch > and have installed the libusb1.0 version of brltty-win > as well, but somewhere, I must have misconfigured > something: the connection seems to get made, but > there is no known HT model with ID e3. > > Any suggestions?
The Braillino 20 has no USB interface, so using -dusb: will not work. I have contacted Handy Tech to double check about the ID 0XE3, but as expected, they have never produced a device with such an ID. The Braillino 20 should have ID 0X72. I am suspecting data corruption, or misconfiguration. Do you perhaps have several devices connect to serial ports on that machine, and accidentally picking the wrong port? The identification protocol of Handy Tech devices is not very verbose, so there is a certain chance of detecting random data from other devices as unknown IDs, which I think is what you are seeing right now. -- CYa, ⡍⠁⠗⠊⠕ _______________________________________________ This message was sent via the BRLTTY mailing list. To post a message, send an e-mail to: [email protected] For general information, go to: http://mielke.cc/mailman/listinfo/brltty