I have a SunFire T2000 that I've chopped up into LDOMs. The primary domain
and six of the LDOMs are running 6.1-STABLE just fine. I pulled down the
May 22 snapshot, and it installs (with a strange error, see bottom of
post), but the LDOM crashes upon boot. I just tried again with the May 24th
snapshot, and I'm getting the same error. This seems to dump me into
OpenBoot, not ddb. I can provide a shell on the primary domain, and serial
console (over ssh) access to a developer if needed. I am not subscribed to
bugs@, so please copy me off-list.


Sun Fire T200, No Keyboard
Copyright 2010 Sun Microsystems, Inc.  All rights reserved.
OpenBoot 4.30.4.a, 3072 MB memory available, Serial #83548683.
Ethernet address 0:14:4f:fa:da:b, Host ID: 84fada0b.


Boot device: disk  File and args:
OpenBSD IEEE 1275 Bootblock 1.4
..>> OpenBSD BOOT 1.9
Trying bsd...
Booting /virtual-devices@100/channel-devices@200/disk@0:a/bsd
8381472@0x1000000+7136@0x17fe420+196864@0x1800000+3997440@0x1830100
symbols @ 0xfedcc3c0 155+553992+364844 start=0x1000000
[ using 919960 bytes of bsd ELF symbol table ]
console is /virtual-devices@100/console@1
Copyright (c) 1982, 1986, 1989, 1991, 1993
        The Regents of the University of California.  All rights reserved.
Copyright (c) 1995-2017 OpenBSD. All rights reserved.
https://www.OpenBSD.org

OpenBSD 6.1-current (GENERIC.MP) #123: Tue May 23 21:16:40 MDT 2017
    dera...@sparc64.openbsd.org:/usr/src/sys/arch/sparc64/compile/GENERIC.MP
real mem = 3221225472 (3072MB)
avail mem = 3145572352 (2999MB)
mpath0 at root
scsibus0 at mpath0: 256 targets
mainbus0 at root: Sun Fire T200
cpu0 at mainbus0: SUNW,UltraSPARC-T1 (rev 0.0) @ 1200 MHz
cpu1 at mainbus0: SUNW,UltraSPARC-T1 (rev 0.0) @ 1200 MHz
cpu2 at mainbus0: SUNW,UltraSPARC-T1 (rev 0.0) @ 1200 MHz
cpu3 at mainbus0: SUNW,UltraSPARC-T1 (rev 0.0) @ 1200 MHz
vbus0 at mainbus0
"flashprom" at vbus0 not configured
cbus0 at vbus0
vdsk0 at cbus0 chan 0x2: ivec 0x4, 0x5
scsibus1 at vdsk0: 2 targets
sd0 at scsibus1 targ 0 lun 0: <SUN, Virtual Disk, 1.1> SCSI3 0/direct fixed
sd0: 4000MB, 512 bytes/sector, 8192000 sectors
vnet0 at cbus0 chan 0x3: ivec 0x6, 0x7, address 00:14:4f:f9:ce:e5
vcons0 at vbus0: ivec 0x111, console
vrtc0 at vbus0
vscsi0 at root
scsibus2 at vscsi0: 256 targets
softraid0 at root
scsibus3 at softraid0: 256 targets
bootpath: /virtual-devices@100,0/channel-devices@200,0/disk@0,0
root on sd0a (65ce554ceba2f574.a) swap on sd0b dump on sd0b

ERROR: Last Trap: Fast Data Access Protection

{1} ok


=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=

* one odd thing happens during install:
fatal in dhclient: yielding responsibility for vnet0

I worked around it by ^Z and manually running dhclient from the shell
before foregrounding it. Full install log up to the error included below.


OpenBSD 6.1-current (RAMDISK) #116: Mon May 22 13:59:22 MDT 2017
    dera...@sparc64.openbsd.org:/usr/src/sys/arch/sparc64/compile/RAMDISK
real mem = 3221225472 (3072MB)
avail mem = 3150954496 (3004MB)
mainbus0 at root: Sun Fire T200
cpu0 at mainbus0: SUNW,UltraSPARC-T1 (rev 0.0) @ 1200 MHz
"SUNW,UltraSPARC-T1" at mainbus0 not configured
"SUNW,UltraSPARC-T1" at mainbus0 not configured
"SUNW,UltraSPARC-T1" at mainbus0 not configured
vbus0 at mainbus0
"flashprom" at vbus0 not configured
cbus0 at vbus0
vdsk0 at cbus0 chan 0x2: ivec 0x4, 0x5
scsibus0 at vdsk0: 2 targets
sd0 at scsibus0 targ 0 lun 0: <SUN, Virtual Disk, 1.1> SCSI3 0/direct fixed
sd0: 4000MB, 512 bytes/sector, 8192000 sectors
vnet0 at cbus0 chan 0x3: ivec 0x6, 0x7, address 00:14:4f:f9:ce:e5
vcons0 at vbus0: ivec 0x111, console
vrtc0 at vbus0
softraid0 at root
scsibus1 at softraid0: 256 targets
bootpath: /virtual-devices@100,0/channel-devices@200,0/disk@0,0
root on rd0a swap on rd0b dump on rd0b
erase ^?, werase ^W, kill ^U, intr ^C, status ^T

Welcome to the OpenBSD/sparc64 6.1 installation program.
(I)nstall, (U)pgrade, (A)utoinstall or (S)hell? i
At any prompt except password prompts you can escape to a shell by
typing '!'. Default answers are shown in []'s and are selected by
pressing RETURN.  You can exit this program at any time by pressing
Control-C, but this can leave your system in an inconsistent state.

System hostname? (short form, e.g. 'foo') puffyfivesnap

Available network interfaces are: vnet0 vlan0.
Which network interface do you wish to configure? (or 'done') [vnet0]
IPv4 address for vnet0? (or 'dhcp' or 'none') [dhcp]
DHCPDISCOVER on vnet0 - interval 1
fatal in dhclient: yielding responsibility for vnet0
IPv6 address for vnet0? (or 'autoconf' or 'none') [none] ^Z
[1] + Suspended            /install
# dhclient vnet0
DHCPDISCOVER on vnet0 - interval 1
DHCPOFFER from 192.168.1.254 (f8:18:97:8f:a5:09)
DHCPREQUEST on vnet0 to 255.255.255.255
DHCPACK from 192.168.1.254 (f8:18:97:8f:a5:09)
bound to 192.168.1.70 -- renewal in 43200 seconds.
# fg
/install

Available network interfaces are: vnet0 vlan0.
Which network interface do you wish to configure? (or 'done') [done]
Using DNS domainname attlocal.net
Using DNS nameservers at 192.168.1.254


TIA
--ax0n
http://www.h-i-r.net/