Hi Drew,
I ran a 175 install and it all worked as advertised. Very cool and thanks for
the quick responses. Much appreciated.
- Brian
Brian Phipps | Software Engineer | +1.503.495.7716
Oracle World Wide Operations
On Oct 13, 2011, at 3:36 PM, Drew Fisher wrote:
> Brian,
>
> I think you're running into CR 7083584 which was fixed in b174. What's
> happening is the auto-installer service is starting before the fmd and
> devchassis services are coming online which prevents AI from finding disks
> with croinfo receptacle names.
>
> Could I get you to try installing b174?
>
> -Drew
>
> On 10/13/11 4:03 PM, Brian Phipps wrote:
>>
>> I'm installing b173 using a b175 AI server running a b175 AI service. I"m
>> attempting to install to a new sparc based T4-4 server.
>>
>> root@ht72mdc9:~# format
>> Searching for disks...done
>>
>>
>> AVAILABLE DISK SELECTIONS:
>> 0. c0t5000CCA01248AC8Cd0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt
>> 2 hd 27 sec 668>
>> /scsi_vhci/disk@g5000cca01248ac8c
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD0/disk
>> 1. c0t5000CCA01248923Cd0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt
>> 2 hd 27 sec 668>
>> /scsi_vhci/disk@g5000cca01248923c
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD1/disk
>> 2. c0t5000CCA0124862D0d0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt
>> 2 hd 27 sec 668>
>> /scsi_vhci/disk@g5000cca0124862d0
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD2/disk
>> 3. c0t5000CCA0124892B4d0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt
>> 2 hd 27 sec 668>
>> /scsi_vhci/disk@g5000cca0124892b4
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD3/disk
>> 4. c0t5000CCA01243E944d0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt
>> 2 hd 27 sec 668>
>> /scsi_vhci/disk@g5000cca01243e944
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD4/disk
>> 5. c0t5000CCA0123F37C0d0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt
>> 2 hd 27 sec 668>
>> /scsi_vhci/disk@g5000cca0123f37c0
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD5/disk
>> 6. c0t50015179595677A4d0 <ATA-INTEL SSDSA2BZ30-0362 cyl 35769 alt 2
>> hd 128 sec 128>
>> /scsi_vhci/disk@g50015179595677a4
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD6/disk
>> 7. c0t5001517959568223d0 <ATA-INTEL SSDSA2BZ30-0362 cyl 35769 alt 2
>> hd 128 sec 128>
>> /scsi_vhci/disk@g5001517959568223
>> /dev/chassis/ORCL,SPARC-T4-4.1128BDY7C5//SYS/MB/HDD7/disk
>> Specify disk (enter its number):
>>
>>
>> root@ht72mdc9:~# croinfo -O cR
>> c0t5000CCA01248AC8Cd0:/SYS/MB/HDD0
>> c0t5000CCA01248923Cd0:/SYS/MB/HDD1
>> c0t5000CCA0124862D0d0:/SYS/MB/HDD2
>> c0t5000CCA0124892B4d0:/SYS/MB/HDD3
>> c0t5000CCA01243E944d0:/SYS/MB/HDD4
>> c0t5000CCA0123F37C0d0:/SYS/MB/HDD5
>> c0t50015179595677A4d0:/SYS/MB/HDD6
>> c0t5001517959568223d0:/SYS/MB/HDD7
>>
>>
>>
>>
>> - Brian
>>
>>
>> Brian Phipps | Software Engineer | +1.503.495.7716
>> Oracle World Wide Operations
>>
>> On Oct 13, 2011, at 12:28 PM, Drew Fisher wrote:
>>
>>> Brian,
>>>
>>> I have a few questions for you:
>>>
>>> What build are you installing? What kind of machine are you attempting to
>>> install to? Can you attach the output from format?
>>>
>>> Thanks!
>>>
>>> -Drew
>>>
>>> On 10/13/11 1:10 PM, Brian Phipps wrote:
>>>>
>>>> Hi All,
>>>>
>>>> I'm not sure if I've configured something incorrectly in my AI manifest or
>>>> if I'm hitting a bug. Pointers in the right direction would be much
>>>> appreciated.
>>>>
>>>> I'm using the following targets in my AI manifest per croinfo -O cR:
>>>>
>>>> <disk whole_disk="true">
>>>> <disk_name name="/SYS/MB/HDD0" name_type="receptacle"/>
>>>> <slice name="0" in_zpool="rpool" action="create"
>>>> force="true">
>>>> <size val="279gb"/>
>>>> </slice>
>>>> <slice name="1" action="create" force="true"/>
>>>> </disk>
>>>>
>>>>
>>>>
>>>> It looks to my that the disks are being discovered in the install_log:
>>>>
>>>> 2011-10-13 18:40:30,346 InstallationLogger.target-selection DEBUG
>>>> discovered =
>>>> -> [discovered] (<solaris_install.target.Target object at
>>>> 0xe03070>)
>>>> -> [disk] (Disk: ctd=c0t5000CCA01243E944d0;
>>>> volid=None; devpath=/scsi_vhci/disk@g5000cca01243e944;
>>>> devid=id1,sd@n5000cca01243e944; prop:dev_type=scsi;
>>>> prop:dev_vendor=HITACHI; prop
>>>> :dev_size=558.89gb; is_cdrom=False; label=VTOC; whole_disk=False;
>>>> write_cache=False)
>>>> -> [0] (Slice: name=0; action=preserve,
>>>> force=False, is_swap=False, tag=2, flag=0; size=132.10mb; start_sector=0)
>>>> -> [1] (Slice: name=1; action=preserve,
>>>> force=False, is_swap=False, tag=3, flag=1; size=132.10mb;
>>>> start_sector=270540)
>>>> -> [2] (Slice: name=2; action=preserve,
>>>> force=False, is_swap=False, tag=5, flag=1; size=558.89gb; start_sector=0)
>>>> -> [6] (Slice: name=6; action=preserve,
>>>> force=False, is_swap=False, tag=4, flag=0, in_use={'used_by': ['fs'],
>>>> 'used_name': ['ufs']}; size=558.64gb; start_sector=541080)
>>>>
>>>>
>>>> But the install fails with these messages:
>>>>
>>>> 2011-10-13 18:40:30,532 InstallationLogger.target-selection DEBUG
>>>> Processing disk : [receptacle='/SYS/MB/HDD0']
>>>> 2011-10-13 18:40:30,564 InstallationLogger.target-selection DEBUG
>>>> Traceback (most recent call last):
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3403, in execute
>>>> self.select_targets(from_manifest, discovered, dry_run)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3298, in select_targets
>>>> new_target = self.__handle_target(from_manifest[0])
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3090, in __handle_target
>>>> new_disk = self.__handle_disk(disk)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 2571, in __handle_disk
>>>> self.__pretty_print_disk(disk))
>>>> SelectionError: Unable to locate the disk '[receptacle='/SYS/MB/HDD0']' on
>>>> the system.
>>>>
>>>> 2011-10-13 18:40:30,564 InstallationLogger ERROR Error occurred
>>>> during execution of 'target-selection' checkpoint.
>>>> Traceback (most recent call last):
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/engine/__init__.py",
>>>> line 805, in _execute_checkpoints
>>>> checkpoint.execute(dry_run)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3403, in execute
>>>> self.select_targets(from_manifest, discovered, dry_run)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3298, in select_targets
>>>> new_target = self.__handle_target(from_manifest[0])
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3090, in __handle_target
>>>> new_disk = self.__handle_disk(disk)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 2571, in __handle_disk
>>>> self.__pretty_print_disk(disk))
>>>> SelectionError: Unable to locate the disk '[receptacle='/SYS/MB/HDD0']' on
>>>> the system.
>>>> 2011-10-13 18:40:30,623 InstallationLogger ERROR Aborting: Internal
>>>> error in InstallEngine
>>>> Traceback (most recent call last):
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/engine/__init__.py",
>>>> line 805, in _execute_checkpoints
>>>> checkpoint.execute(dry_run)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3403, in execute
>>>> self.select_targets(from_manifest, discovered, dry_run)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3298, in select_targets
>>>> new_target = self.__handle_target(from_manifest[0])
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3090, in __handle_target
>>>> new_disk = self.__handle_disk(disk)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 2571, in __handle_disk
>>>> self.__pretty_print_disk(disk))
>>>> SelectionError: Unable to locate the disk '[receptacle='/SYS/MB/HDD0']' on
>>>> the system.
>>>> 2011-10-13 18:40:30,674 InstallationLogger ERROR Target selection
>>>> checkpoint error:
>>>> 2011-10-13 18:40:30,725 InstallationLogger ERROR Unable to
>>>> locate the disk '[receptacle='/SYS/MB/HDD0']' on the system.
>>>> 2011-10-13 18:40:30,795 InstallationLogger DEBUG Traceback (most
>>>> recent call last):
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/auto_install.py",
>>>> line 804, in execute_checkpoints
>>>> dry_run=dry_run, callback=None)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/engine/__init__.py",
>>>> line 525, in execute_checkpoints
>>>> thread.start()
>>>> File "/usr/lib/python2.6/threading.py", line 477, in run
>>>> self.__target(*self.__args, **self.__kwargs)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/engine/__init__.py",
>>>> line 805, in _execute_checkpoints
>>>> checkpoint.execute(dry_run)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3403, in execute
>>>> self.select_targets(from_manifest, discovered, dry_run)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3298, in select_targets
>>>> new_target = self.__handle_target(from_manifest[0])
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 3090, in __handle_target
>>>> new_disk = self.__handle_disk(disk)
>>>> File
>>>> "/usr/lib/python2.6/vendor-packages/solaris_install/auto_install/checkpoints/target_selection.py",
>>>> line 2571, in __handle_disk
>>>> self.__pretty_print_disk(disk))
>>>> SelectionError: Unable to locate the disk '[receptacle='/SYS/MB/HDD0']' on
>>>> the system.
>>>>
>>>> 2011-10-13 18:40:30,796 InstallationLogger INFO Automated
>>>> Installation Failed. See install log at /system/volatile/install_log
>>>> 2011-10-13 18:40:30,846 InstallationLogger DEBUG Shutting down
>>>> Progress Handler
>>>>
>>>>
>>>> - Brian
>>>>
>>>>
>>>> Brian Phipps | Software Engineer | +1.503.495.7716
>>>> Oracle World Wide Operations
>>>>
>>>>
>>>>
>>>> _______________________________________________
>>>> caiman-discuss mailing list
>>>> [email protected]
>>>> http://mail.opensolaris.org/mailman/listinfo/caiman-discuss
>>
_______________________________________________
caiman-discuss mailing list
[email protected]
http://mail.opensolaris.org/mailman/listinfo/caiman-discuss