With the new spandsp indicated by Max the situation changed in this way:

yesterday was:

WellGate 3701B  HandyTone486            XXXX

SEND FAIL               SEND FAIL                       IAXMODEM
RCV OK          RCV FAIL

SEND OK         SEND FAIL                       PSTN PHYSICAL FAX machine
RCV OK          RCV FAIL


Today is:
WellGate 3701B  HandyTone486            XXXX

SEND FAIL               SEND FAIL                       IAXMODEM
RCV OK          RCV OK

SEND OK         SEND OK                 PSTN PHYSICAL FAX machine
RCV OK          RCV OK                                          


So yesterday I had problem with wellgate only sending faxes to iaxmodem and
I had handytone absolutely not working

Today  nothing changed towards IAXMODEM, but grandstrem became equal to
WellGate 

The only difference seems to be the T38MaxFaxRate, which is 14400 found for
wellgate and 9600 found for handytone.

I am using spandsp indicated by Max (19 of June) and rc4 version of
callweaver (no daily snapshoot)

When dialing to iaxmodem you can ear the handshaking start, then suddenly
stop.