The 450  Cambium is neither UBNT / Mikrotik nor legacy Canopy. A 3rd way. We 
use the dongles despite the price so there will be some clue inside the power 
injector CMM4 If we get the urge to swap some cables to test a port. 
Theoretically makes less smoke.

David

-----Original Message-----
From: "Jan Van Kort" <j.vank...@oregononline.net>
Sent: ‎4/‎5/‎2017 5:41 PM
To: "Cambium Networks User Group" <cambium-users@wispa.org>
Subject: Re: [Cambium-users] smoked it

Ah, the old Betmax vs VHS routine.  Swapping the pairs won't mess up the 
signal?


On 17-04-05 01:14 PM, Nick Bright wrote:
> On 3/31/2017 3:03 PM, Steve D wrote:
>> Ha, their classic POE standard is from the motorola era before anyone
>> was doing POE standards (I'm sure they existed, just ignored).
> There weren't and aren't any POE standards lower than 48v, just some
> de-facto industry standards. At the time in the early 2000's, there was
> not an industry de-facto standard for lower voltage; Cambium was one of
> the first with 30v blue negative/brown positive. The rest of the
> industry eventually went with blue positive/brown negative.
>
>> http://www.linktechs.net/productcart/pc/viewPrd.asp?idproduct=2265&idcategory=
>> might be what you're looking for but it's male to male and I'd guess
>> you'd want male to female.
> http://tyconsystems.com/index.php/passive/554-poe-xover-s tycon makes a
> Socket to Plug adapter.
>
> You could also easily fabricate one with a hunk of cable, a keystone
> jack, and a plug; just swap the blue and brown pairs on one end.
>

_______________________________________________
Cambium-users mailing list
Cambium-users@wispa.org
http://lists.wispa.org/mailman/listinfo/cambium-users
_______________________________________________
Cambium-users mailing list
Cambium-users@wispa.org
http://lists.wispa.org/mailman/listinfo/cambium-users

Reply via email to