hi laura,

are you trying to clock your FGPA at 200 or 400 MHz?

if you configure the ADC yellow block to input 4 samples per clock,
and sampling at 1600 Msps, then you will need to clock your
fpga at 400 MHz, which is pretty near impossible for virtex 5
and you'll get lots of timing errors.

if you configure the yellow block to input 8 samples per clock,
and sampling at 1600 Msps, then the FGPA is clocking at 200 MHz,
and routing and timing should work.

best wishes,

dan

On 5/13/2010 6:46 PM, Laura Spitler wrote:
Hi everyone,

Does anyone have a sense of whether a dual polarization, 800 MHz
spectrometer with ~2k channels would fit into a ROACH? I have a test
design using the ADC083000 and and two small wideband FFTs. It seems
to work in terms of utilization, but I get a crazy number of timing
errors.
Has anyone successfully built anything like this?

Thanks,
Laura



Reply via email to