Hi all.  We've had a couple of ROACH failures with identical causes. 
Maybe some of you have seen this, but it's worth keeping in mind in case
you have a problem.

The symptom is that the ROACH would sort of power on, but then turn off
spontaneously.  On one, as soon as the bof was loaded the roach would turn
off.  The other one would come on for a brief few seconds and then turn
or, or it would cycle on and off.  The monitor readout in dmesg gave
non-sense readings.

In any event, the cause was traced to the +1 volt supply MOSFET switch. 
Replacing that mosfet fixed both roaches.  Kudos to Jason Ray for finding
the problem originally.

John



Reply via email to