hi john, the only special blocks i can think of for IQ spectrometers are the optional blocks and architecture that glenn developed, discussed in glenn's thesis, to improve image rejection by correcting for gain and phase mismatches in the IF system before the ADC's (gain and phase errors in the low pass filters, mixers, and 90 degree splitter can be corrected digitally).
best wishes, dan On Fri, Nov 7, 2014 at 12:12 PM, John Ford <[email protected]> wrote: >> Several of the MKID systems use I/Q inputs. There's no real trick, they >> just go through PFB_FIR real blocks (one for each I and Q) and then into >> the classic fft block as the real and imag parts of the input data. > > Thanks, Glenn.. I was wondering if there were any special blocks used > that we didn't typically think of. > > John > >> >> On Fri, Nov 7, 2014 at 1:57 PM, John Ford <[email protected]> wrote: >> >>> Hi all. Are there any example spectrometers or correlators that use I/Q >>> sampling as opposed to the usual real-valued ADCs we generally use >>> nowadays? It seems like some early designs used these. >>> >>> We need to build a design that uses an I/Q stream as input, and we'd >>> like >>> to get a jump start on it by starting with a working model. >>> >>> Thanks! >>> >>> John >>> >>> >>> >>> >> > > >