Marking multiple fields in the same packet with CB Policing is called
multi-action policing, I think that I've tried this once and it worked out.

 

Regards,

Masood Ahmad Shah

 

 

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Ibrahim Yassir
Sent: Friday, August 03, 2007 6:36 PM
To: [email protected]
Subject: [OSL | CCIE_RS] MQC police actions

 

Hello,

 

Dose anyone know if it is possible to use multiple actions in a policy-map
when policing?

It is possible to configure but I'm not sure if it works

 

The configuration:

 

policy-map FR-POLICE

 class class-default

  police cir 128000 

    conform-action transmit 

    exceed-action set-prec-transmit 3          ! The first exceed action

    exceed-action set-frde-transmit              ! The second exceed action

 

 

interface Serial0/3/0

 description To FR-Switch S0/0

 ip address 150.50.12.1 255.255.255.0

 encapsulation frame-relay

 service-policy output FR-POLICE

 

 

In this case I want to set the prec and also set the DE bit.

 

Thanks

/Yassir

 