Marking multiple fields in the same packet with CB Policing is called multi-action policing, I think that I've tried this once and it worked out.
Regards, Masood Ahmad Shah From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Ibrahim Yassir Sent: Friday, August 03, 2007 6:36 PM To: [email protected] Subject: [OSL | CCIE_RS] MQC police actions Hello, Dose anyone know if it is possible to use multiple actions in a policy-map when policing? It is possible to configure but I'm not sure if it works The configuration: policy-map FR-POLICE class class-default police cir 128000 conform-action transmit exceed-action set-prec-transmit 3 ! The first exceed action exceed-action set-frde-transmit ! The second exceed action interface Serial0/3/0 description To FR-Switch S0/0 ip address 150.50.12.1 255.255.255.0 encapsulation frame-relay service-policy output FR-POLICE In this case I want to set the prec and also set the DE bit. Thanks /Yassir