I have a link with a provider spanning two locations. The provider is
running QinQ and we have a trunk setup across the link. Recently we had the
requirement to start doing QnQ for a few "customers" so we attempted to do
QinQ for our downstream neighbors. The problem is, when our downstream
"customer" plugs in one switch, our port on the provider side goes into
errdisable due to l2ptguard.

I believe if the customer plugs a switch on the other side, the link will
come up and be fine. The problem is, we can't afford to lose our link
because the customer had a switch die or is missing a switch on one side for
some other reason.

The only solution i can think up is to have the provider disable errdiable
for the l2ptguard cause.

Does anyone else have any ideas, suggestion?

Thanks,

Justin