I don't think the same command exists. You have:
set power redundancy enable | disable
With redundancy enabled being the default. The load sharing and
redundancy is automatically handled, and is not configurable. See
http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/catos/8.x/configuration/guide/admin.html#wp1020356
for a chart.
-Tim
On 2/3/10 1:32 AM, Taqdir Singh wrote:
no its not. I tried in catOS.
On Wed, Feb 3, 2010 at 12:40 AM, Marko Milivojevic
<[email protected] <mailto:[email protected]>> wrote:
On Tue, Feb 2, 2010 at 18:33, Taqdir Singh <[email protected]
<mailto:[email protected]>> wrote:
> Hi,
>
> could you please tell what is equivalent of IOS command in
catOS-6500 ?
>
> power redundancy-mode combined | redundant