Ok I dont really know what's behind or within the cloud . So it would mean that some other routers would advertise their DLCI via INARP to some FRSWITCH and that FRSWITCH is sending me the results hence the fact that I got several DLCI and maps from Others subnets ?
I thought that I would only see informations about "connected" host within the FR cloud Thanks for the help 2010/9/22 Jay Taylor <[email protected]> > Inverse ARP will do that when multiple DLCI's are advertised to the DCE. > > > On Wed, Sep 22, 2010 at 2:31 PM, Nicolas MICHEL <[email protected]>wrote: > >> Hey there. >> >> I got a router connected to a FR cloud and here is the config on the >> router >> >> R6#sh run int s0/0/0 >> Building configuration... >> >> Current configuration : 119 bytes >> ! >> interface Serial0/0/0 >> ip address 54.1.1.6 255.255.255.0 >> encapsulation frame-relay >> frame-relay lmi-type cisco >> end >> >> >> >> Cant be simpler can it be ? :D >> >> >> I d like to understand why do I got frame map and LMI DLCI from subnets >> that are not DIRECTLY connected to my interface >> >> R6#sh frame pvc | i DLCI >> DLCI = 51, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = >> Serial0/0/0 >> DLCI = 100, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = >> Serial0/0/0 >> DLCI = 101, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = >> Serial0/0/0 >> DLCI = 201, DLCI USAGE = UNUSED, PVC STATUS = ACTIVE, INTERFACE = >> Serial0/0/0 >> DLCI = 301, DLCI USAGE = UNUSED, PVC STATUS = ACTIVE, INTERFACE = >> Serial0/0/0 >> DLCI = 401, DLCI USAGE = UNUSED, PVC STATUS = ACTIVE, INTERFACE = >> Serial0/0/0 >> >> $R6#sh frame map >> Serial0/0/0 (up): ip 54.1.3.254 dlci 51(0x33,0xC30), dynamic, >> broadcast,, status defined, active >> Serial0/0/0 (up): ip 54.1.2.254 dlci 100(0x64,0x1840), dynamic, >> broadcast,, status defined, active >> Serial0/0/0 (up): ip 54.1.1.254 dlci 101(0x65,0x1850), dynamic, >> broadcast,, status defined, active >> >> >> Seeking the informations in books and will post if I find >> -- >> Nicolas MICHEL >> Ingenieur Réseaux et Securité (CCNA/CCNP and CCIE Pending) >> Centre d’Expertise et d’Assistance Clients >> Spie communication >> Tél : +33 (0)141464924 >> Mob: +33 (0)608727597 >> >> >> >> >> >> _______________________________________________ >> For more information regarding industry leading CCIE Lab training, please >> visit www.ipexpert.com >> >> > -- Nicolas MICHEL Ingenieur Réseaux et Securité (CCNA/CCNP and CCIE Pending) Centre d’Expertise et d’Assistance Clients Spie communication Tél : +33 (0)141464924 Mob: +33 (0)608727597
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com