Hi, Can you include a show frame-relay pvc and show frame-relay map?
Cheers, Adam On Tue, Oct 12, 2010 at 10:19 AM, Amer Mustafa <[email protected]>wrote: > *WB1 ==> LAB 11 ==> Task 11.4.* > ** > For some reaon R9 is showing the interface Serial 0/2/0.32 in down/down > state, i have tried some show commands but no clue : > > ------------------------------------------------------------------- > *R9#show int ser 0/2/0* > Serial0/2/0 is up, line protocol is up > Hardware is GT96K Serial > MTU 1500 bytes, BW 1544 Kbit/sec, DLY 20000 usec, > reliability 255/255, txload 1/255, rxload 1/255 > Encapsulation FRAME-RELAY, loopback not set > Keepalive set (10 sec) > CRC checking enabled > LMI enq sent 108, LMI stat recvd 109, LMI upd recvd 0, DTE LMI up > LMI enq recvd 0, LMI stat sent 0, LMI upd sent 0 > LMI DLCI 1023 LMI type is CISCO frame relay DTE > FR SVC disabled, LAPF state down > Broadcast queue 0/64, broadcasts sent/dropped 3/0, interface broadcasts 0 > Last input 00:00:07, output 00:00:07, output hang never > Last clearing of "show interface" counters 00:19:15 > Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0 > Queueing strategy: weighted fair > Output queue: 0/1000/64/0 (size/max total/threshold/drops) > Conversations 0/1/256 (active/max active/max total) > Reserved Conversations 0/0 (allocated/max allocated) > Available Bandwidth 1158 kilobits/sec > 5 minute input rate 0 bits/sec, 0 packets/sec > 5 minute output rate 0 bits/sec, 0 packets/sec > 130 packets input, 8510 bytes, 0 no buffer > Received 0 broadcasts, 0 runts, 0 giants, 0 throttles > 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort > 115 packets output, 2444 bytes, 0 underruns > 0 output errors, 0 collisions, 3 interface resets > 18 unknown protocol drops > 0 output buffer failures, 0 output buffers swapped out > 0 carrier transitions > DCD=up DSR=up DTR=up RTS=up CTS=up > ---------------------------------------- > *R9#show int ser 0/2/0.32 > *Serial0/2/0.32 is down, line protocol is down > Hardware is GT96K Serial > Internet address is 150.50.69.9/25 > MTU 1500 bytes, BW 1544 Kbit/sec, DLY 20000 usec, > reliability 255/255, txload 1/255, rxload 1/255 > Encapsulation FRAME-RELAY > CRC checking enabled > Last clearing of "show interface" counters never > ------------------------------------------- > > The R9 is connecting to R6 and here are the show commands results on R6 : > > R6#show int ser 0/2/0 > Serial0/2/0 is up, line protocol is up > Hardware is GT96K Serial > MTU 1500 bytes, BW 1544 Kbit/sec, DLY 20000 usec, > reliability 255/255, txload 1/255, rxload 1/255 > Encapsulation FRAME-RELAY, loopback not set > Keepalive set (10 sec) > CRC checking enabled > LMI enq sent 0, LMI stat recvd 0, LMI upd recvd 0 > LMI enq recvd 1107, LMI stat sent 1107, LMI upd sent 0, DCE LMI up > LMI DLCI 1023 LMI type is CISCO frame relay DCE > FR SVC disabled, LAPF state down > Broadcast queue 0/64, broadcasts sent/dropped 195/1, interface broadcasts > 0 > Last input 00:00:02, output 00:00:02, output hang never > Last clearing of "show interface" counters 03:08:12 > Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0 > Queueing strategy: weighted fair > Output queue: 0/1000/64/0 (size/max total/threshold/drops) > Conversations 0/1/256 (active/max active/max total) > Reserved Conversations 0/0 (allocated/max allocated) > Available Bandwidth 1158 kilobits/sec > 5 minute input rate 0 bits/sec, 0 packets/sec > 5 minute output rate 0 bits/sec, 0 packets/sec > 1121 packets input, 15874 bytes, 0 no buffer > Received 0 broadcasts, 0 runts, 0 giants, 0 throttles > 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort > 1308 packets output, 81164 bytes, 0 underruns > 0 output errors, 0 collisions, 6 interface resets > 0 unknown protocol drops > 0 output buffer failures, 0 output buffers swapped out > 43 carrier transitions > DCD=up DSR=up DTR=up RTS=up CTS=up > --------------------------------- > > *R6#show int ser 0/2/0.32 > Serial0/2/0.32 is up, line protocol is up* > Hardware is GT96K Serial > Internet address is 150.50.69.6/25 > MTU 1500 bytes, BW 1544 Kbit/sec, DLY 20000 usec, > reliability 255/255, txload 1/255, rxload 1/255 > Encapsulation FRAME-RELAY > CRC checking enabled > Last clearing of "show interface" counters never > > _______________________________________________ > For more information regarding industry leading CCIE Lab training, please > visit www.ipexpert.com > >
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com
