They are also used for TCN BPDUs the switch generates. 

On Feb 26, 2011, at 20:22, Jay Taylor <[email protected]> wrote:

> Transparent mode or in case that switch somehow ends up as root.
> 
> 
> On Sat, Feb 26, 2011 at 8:10 PM, Paul Kim <[email protected]> wrote:
> 
>> It seems that the local timers are worthy configuring either for
>> transparent mode switches or just for single number of switch from vtp
>> domain point of view.
>> Right guess?
>> 
>> Thanks a lot,
>> Paul
>> 
>> On Sat, Feb 26, 2011 at 5:03 PM, Paul Kim <[email protected]> wrote:
>>> Hi Jay,
>>> 
>>> Another question then.
>>> Is there any specific reason that the local timer is present then?
>>> 
>>> Thanks,
>>> Paul
>>> 
>>> On Sat, Feb 26, 2011 at 4:54 PM, Jay Taylor <[email protected]> wrote:
>>>> Yes and yes.
>>>> 
>>>> 
>>>> On Sat, Feb 26, 2011 at 5:45 PM, Paul Kim <[email protected]> wrote:
>>>>> 
>>>>> Dear Experts,
>>>>> 
>>>>> Per my lab test for hello and forward-time over PVST, the locally
>>>>> configured timers at non-root-switch is not being used but the one
>>>>> configured at the root switch.
>>>>> 
>>>>> Is this true with maxage-time?
>>>>> Is it true with RSTP?
>>>>> 
>>>>> Thanks a lot,
>>>>> Paul
>>>>> _______________________________________________
>>>>> For more information regarding industry leading CCIE Lab training,
>> please
>>>>> visit www.ipexpert.com
>>>> 
>>>> 
>>> 
>> 
> _______________________________________________
> For more information regarding industry leading CCIE Lab training, please 
> visit www.ipexpert.com
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to