I thought so as well but ignored it since the DSG showed the use of 567 as port f0/21's native vlan.
Thanks for the insights. On Fri, Apr 1, 2011 at 10:38 PM, Jay Taylor <[email protected]> wrote: > That'd be an ask the proctor situation but without any more information I'd > probably make the native vlan match on both sides. > > > On Fri, Apr 1, 2011 at 2:32 PM, cyrus riobah <[email protected]> wrote: > >> Hi Experts, >> >> Lab 5 on page 145 task 5.5 >> >> When i paste in config >> >> int f0/21 >> switch trunk native vlan 567 >> switch trunk allowed vlan 100,200,300,567 >> >> i get >> >> >> %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on >> FastEthernet0/21 (1), with Cat3 FastEthernet0/21 (567). on Cat1 >> %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on >> FastEthernet0/21 (1), with Cat4 FastEthernet0/21 (567). on Cat2 >> %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on >> FastEthernet0/21 (567), with Cat1 FastEthernet0/21 (1). on Cat3 >> %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on >> FastEthernet0/21 (567), with Cat2 FastEthernet0/21 (1). on Cat4 >> >> The task doesnt say we add any more configs (add the native VLAN to all >> other switches except ones said). >> >> Am I not getting something here? >> >> Please assist! >> >> Regards >> >> Cyrus >> _______________________________________________ >> For more information regarding industry leading CCIE Lab training, please >> visit www.ipexpert.com >> > > _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com