Hi Rene,
I will give you some steps to follow hope will make u do the lab without
disconnecting.
STEPS:
1- open .net file , run the routers put the idlepc & save ur file close.
2- open .net file by using Notepad.
3- under each line of the below put idlemax = 100.
[localhost:7200]
workingdir = C:\CCIE\GNS3\workarea\dynamip-work-dir
udp = 10100
[[3640]]
image = D:\ccie\ios\C3640-IK.bin
idlepc = 0x6050a078
* idlemax = 100 * ========> HERE
idlemax = 100
chassis = 3640
4- Save the file & close.
5- Open the file & Enjoy.
Note: ( under the line console 0 put the following configuration )
*EXEC-TIME 0 0*
*Privi Level 15*
I hope this will help u
On Tue, Sep 13, 2011 at 4:23 PM, René Huet <[email protected]> wrote:
> Hello every body
>
> I have a problem. I work with GNS3 for my CCIE.
>
> All routers boot fine, and I can connect to the console, but after some
> times I lose connection to my console for some routers (the consoles are
> opened but I can't access them)
>
> I have an I7 with a 6 GB of RAM and I work with Ubuntu (but I meet same
> problem with Windows7).
>
> I use the .net file from IPEXPERT (downloaded from tutorial of Scott ).
>
> Please someone can help me ?
> all support is welcome
>
> Best regards
>
> René
>
>
>
> --
> René Paul Huet
>
> Chemin du Réservoir 1b
> 1055 Froideville (Suisse)
>
> tel +41 (0)78.830.76.28
> _______________________________________________
> For more information regarding industry leading CCIE Lab training, please
> visit www.ipexpert.com
>
> Are you a CCNP or CCIE and looking for a job? Check out
> www.PlatinumPlacement.com
>
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit
www.ipexpert.com
Are you a CCNP or CCIE and looking for a job? Check out
www.PlatinumPlacement.com