Hi,

In WB3, Lab3 task2.3, we are asked to configure OSPF with multiple areas 
connected to R6. All the area are connected to area 0 via R7 or R8, in other 
words, there is no area isolated from the backbone. The requirements do not 
specify into which area the loopback must be configured. In picked up an 
existing area at random to advertise the loopback.

In the DSG, without clear explanation, they put the loopback into area 0 and 
then setup virtual-links to avoid partitioned area 0... In real network, I 
would certainly avoid to have a non backbone router connected to multiple areas 
but in the lab it is not a matter of best practices. So why do they configure 
the area 0 on R6? Is it only to avoid sub-optimal routing?

Regards,
Christophe