Hi, In WB3, Lab3 task2.3, we are asked to configure OSPF with multiple areas connected to R6. All the area are connected to area 0 via R7 or R8, in other words, there is no area isolated from the backbone. The requirements do not specify into which area the loopback must be configured. In picked up an existing area at random to advertise the loopback.
In the DSG, without clear explanation, they put the loopback into area 0 and then setup virtual-links to avoid partitioned area 0... In real network, I would certainly avoid to have a non backbone router connected to multiple areas but in the lab it is not a matter of best practices. So why do they configure the area 0 on R6? Is it only to avoid sub-optimal routing? Regards, Christophe _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com Are you a CCNP or CCIE and looking for a job? Check out www.PlatinumPlacement.com