I will suggest you to use rancid

On Fri, Mar 30, 2012 at 12:57 AM, Vijaya Laxmi <[email protected]> wrote:

> Hello,
>
> I am trying to use EEM to store running-config into flash of router every
> time someone changes config
>
> The CATCH is, I want the filename of back up to be dynamic.. based on
> "TimestampHostname.Running.**cfg"
>
> The backup of running config gets stored but filename is WRONG...!
>
> event manager applet SAVE_CONFIG
>  event syslog pattern "%SYS-5-CONFIG.*"
>  action 1.0 cli command "enable"
>  ACTION 1.1 cli command "show clock"
>  action 2.0 cli command "show run | redirect flash://$_cli_result.txt"
>  action 3.0 syslog msg "configuration has been changed"
>
> I could only get the foll file stored at flash of router:-
>
>  *Mar 29 19:19:14.393: %PARSER-5-CFGLOG_LOGGEDCMD: User:unknown user
>  logged command:!exec: enable
> *Mar 29 19:19:15.585: %HA_EM-6-LOG: SAVE: configuration has been changed
> Router#
> Router#dir flash:
> Directory of flash:/
>   11  -rw-        1292  Mar 29 2012 19:19:14 +00:00 _*redirect.out
> *_
> 64012288 bytes total (4603904 bytes free)
>
> Regards
> Vijaya
> ______________________________**_________________
> For more information regarding industry leading CCIE Lab training, please
> visit www.ipexpert.com
>
> Are you a CCNP or CCIE and looking for a job? Check out
> www.PlatinumPlacement.com
>
> http://onlinestudylist.com/**mailman/listinfo/ccie_rs<http://onlinestudylist.com/mailman/listinfo/ccie_rs>
>



-- 
Kaushal
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out 
www.PlatinumPlacement.com

http://onlinestudylist.com/mailman/listinfo/ccie_rs

Reply via email to