I will suggest you to use rancid On Fri, Mar 30, 2012 at 12:57 AM, Vijaya Laxmi <[email protected]> wrote:
> Hello, > > I am trying to use EEM to store running-config into flash of router every > time someone changes config > > The CATCH is, I want the filename of back up to be dynamic.. based on > "TimestampHostname.Running.**cfg" > > The backup of running config gets stored but filename is WRONG...! > > event manager applet SAVE_CONFIG > event syslog pattern "%SYS-5-CONFIG.*" > action 1.0 cli command "enable" > ACTION 1.1 cli command "show clock" > action 2.0 cli command "show run | redirect flash://$_cli_result.txt" > action 3.0 syslog msg "configuration has been changed" > > I could only get the foll file stored at flash of router:- > > *Mar 29 19:19:14.393: %PARSER-5-CFGLOG_LOGGEDCMD: User:unknown user > logged command:!exec: enable > *Mar 29 19:19:15.585: %HA_EM-6-LOG: SAVE: configuration has been changed > Router# > Router#dir flash: > Directory of flash:/ > 11 -rw- 1292 Mar 29 2012 19:19:14 +00:00 _*redirect.out > *_ > 64012288 bytes total (4603904 bytes free) > > Regards > Vijaya > ______________________________**_________________ > For more information regarding industry leading CCIE Lab training, please > visit www.ipexpert.com > > Are you a CCNP or CCIE and looking for a job? Check out > www.PlatinumPlacement.com > > http://onlinestudylist.com/**mailman/listinfo/ccie_rs<http://onlinestudylist.com/mailman/listinfo/ccie_rs> > -- Kaushal _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com Are you a CCNP or CCIE and looking for a job? Check out www.PlatinumPlacement.com http://onlinestudylist.com/mailman/listinfo/ccie_rs