Hi,

I ll try it and give you a conclusion..

Thanks to all,

AH


--- On Mon, 6/9/08, Devildoc <[EMAIL PROTECTED]> wrote:

> From: Devildoc <[EMAIL PROTECTED]>
> Subject: RE: [OSL | CCIE_Voice] CallManager NTP Syncrhonization with NTP 
> Master
> To: [EMAIL PROTECTED], "Stephen Collinson" <[EMAIL PROTECTED]>, [EMAIL 
> PROTECTED]
> Cc: "ccievoice" <ccie_voice@onlinestudylist.com>
> Date: Monday, June 9, 2008, 6:16 PM
> Well, you answered your own question right there.  The
> "clock summer-time UTC recurring" on the NTP
> master would offset the time synch with CM Server.  So you
> 2 options. Option #1, use "clock summer-time UTC
> recurring" on the NTP master and enable DST on CCM
> server.  Or option #2, do not use "clock summer-time
> UTC recurring" on the NTP master and disable DST on
> CCM server.
>  
> JD
>  
>  
> > Date: Mon, 9 Jun 2008 10:44:54 -0700> From:
> [EMAIL PROTECTED]> Subject: [OSL | CCIE_Voice]
> CallManager NTP Syncrhonization with NTP Master> To:
> [EMAIL PROTECTED]; [EMAIL PROTECTED];
> [EMAIL PROTECTED]> CC:
> ccie_voice@onlinestudylist.com> > > Hi guys,>
> > The CM I am running is the one abailable with Proctor
> Labs (4.1.3sr3c).> > I already made sure that the
> "Automatically adjust clock for daylight> saving
> changes" is definitely UNCHECKED..> > But still,
> I have the CallManager [15:00] earlier by one hour from the
> NTP master [16:00] ...> > I am suspecting it might
> have to do with the command:> > "clock
> summer-time UTC recurring" on the NTP master since
> behavior of this command is subject to local country
> setting AT the TIME and DATE of applying the command but
> still I am not sure.> > I know my question sounds
> somehow trivial, but I also know that any timing mistake
> might reduce our points in real lab..> > Any
> clue?> > Thanks,> > AH> > --- On Mon,
> 6/9/08, Devildoc <[EMAIL PROTECTED]> wrote:>
> > > From: Devildoc <[EMAIL PROTECTED]>>
> > Subject: RE: [OSL | CCIE_Voice] CallManager NTP
> Syncrhonization with NTP Master> > To:
> [EMAIL PROTECTED], "Stephen Collinson"
> <[EMAIL PROTECTED]>> > Cc:
> "ccievoice"
> <ccie_voice@onlinestudylist.com>> > Date:
> Monday, June 9, 2008, 4:59 PM> > Your CM server is
> using Daylight Saving Time by default. If> > you
> don't want your CM server to use Daylight Saving>
> > Time, then do the followings:> > > > 1.
> Double-click the clock on the task bar to open up the>
> > Date and Time Properties window> > 2. Select the
> Timezone tab> > 3. Uncheck "Automatically adjust
> clock for daylight> > saving changes"> >
> > > That should do it!!!> > > > JD>
> > > Date: Mon, 9 Jun 2008 08:25:18 -0700>
> From:> > [EMAIL PROTECTED]> To:
> [EMAIL PROTECTED]>> > CC:
> ccie_voice@onlinestudylist.com> Subject: [OSL |> >
> CCIE_Voice] CallManager NTP Syncrhonization with NTP>
> > Master> > > Hi Stephen,> > I keep
> same> > timezone setting [UCT +3] on both CallManager
> and NTP> > master, but still I have, let us say:>
> > CallManager> > 15:00> > NTP master:
> 16:00> > Any clue?>> > > AH> > >
> > > --- On Mon, 6/9/08, Stephen> > Collinson
> <[EMAIL PROTECTED]> wrote:> >> >
> > From: Stephen Collinson> >
> <[EMAIL PROTECTED]>> > Subject: RE:>
> > [OSL | CCIE_Voice] CallManager NTP Syncrhonization with
> NTP> > Master> > To: [EMAIL PROTECTED]> >
> Date:> > Monday, June 9, 2008, 3:00 PM> > At
> least 2 things> > you can do.> > > > -
> Change timezone on ntp> > master. > > - Change
> windows. As you say the> > summertime is moving
> it> > forward 1 hour.> >> > > >
> Normally I leave all clocks on 1 timezone (UCT or> >
> EST), to> > keep all logs in> > sync.>
> >> > > > I have not checked NTP RFC to see
> if it always> > assumes UCT> > or if the
> offset> > is passed as> > part of the protocol.
> One can see by changing> >> > timezone xmit>
> > pkts are updated to new timezone.> > Which could
> give you a> > slightly strange> >> >
> result if you update NTP master to +3 and then set> >
> Windows> > to +3. > > > > This is all>
> > just from quick test, so don't take it as>
> >> > gospel.> > > > S> > >
> >> > -----Original Message-----> > From:>
> > [EMAIL PROTECTED]> >>
> > [mailto:[EMAIL PROTECTED] On>
> > Behalf> > Of Ahmed Hamed> > Sent: 09 June
> 2008> > 15:27> > To: ccievoice> >
> Subject: [OSL |> > CCIE_Voice] CallManager NTP
> Syncrhonization> > with> > NTP Master> >
> > > > > Hi,> > >> > >
> Whenever I try to syncrhonize CallManager server with>
> > NTP> > master (hq-rtr for> > example)
> using> > "ntpdate" command, the
> callmanager> >> > server clock gets updated>
> > alright but with a> > difference of exactly one
> hour..> > > > I think> > this is related
> to summer time saving, but cannot> >> > figure
> out how to> > solve this problem.> >> >
> > > I am having the following commands configured
> on> > the ntp> > master:> > > >
> clock timezone> > UTC +3> > clock summer-time
> recurring> > >> > > and in the ntp.conf
> file, I have the following> > configured:> >
> > > server x.y.z.w (ip address> > of ntp
> master)> > fudge x.y.z.w (ip address of ntp> >
> master)> > > > NTP service and Windows time>
> > services are stopped, after> > that ntpdate
> is>> > > executed, then both services are
> started.> >> > > > Please advise,>
> > > > AH> >> > > > > >
> _________________________________________________________________>
> > Now you can invite friends from Facebook and other
> groups> > to join you on Windows Live™ Messenger.
> Add now.> >
> https://www.invite2messenger.net/im/?source=TXT_EML_WLH_AddNow_Now>
> > > > 