Not this time

I prefix 011331322 because I now on pod 12

And I receive that "Called Number=33132433313223001"

So I receive this extra digit "3313243"

So past Thursday a tech call me from IP EXPERT to change Translation in 
PSTN-WAN to fix the problem.

Thanks

David Corbeil
Consultant en technologie | Technology Consultant
Tel. 514-215-2490 | Fax. 514-748-5333
Membre de l'équipe TELUS
________________________________
From: Michael Shavrov [mailto:[EMAIL PROTECTED]
Sent: Sunday, October 05, 2008 11:24 AM
To: David Corbeil
Cc: ccie_voice@onlinestudylist.com
Subject: Re: [OSL | CCIE_Voice] GK calls failed - Receive wrong digit 
fromPSTN-WAN

Hi David,

First of all, you should carefully check your "voice translation-rule" and your 
"num-exp". Looks like you have some runaway translations, which insert and/or 
drop digits into your dialing string.

When you look really close to your digits, you will notice that they are not 
that much "garbage":

1. You dial "3001" with the prefix "001331328", which results as:    
011-331-328-3001 (by the way, what is the tech-prefix???)

2. Your "debug vpm signal" shows similar digits with some "missing and some 
"extra" digits within:    [missing 3] 31 [missing 3] 2 [extra 4] 8-3001

3. And your "debug voice ccapi inout" shows: 331 324 8300 (another 
representation: 331-32 [extra 4] 8-300 [missing 1])

Good luck,

Mike
----
http://cciev.headsetadapter.com


----- Original Message -----
From: David Corbeil<mailto:[EMAIL PROTECTED]>
To: 'ccie_voice@onlinestudylist.com'<mailto:'ccie_voice@onlinestudylist.com'>
Sent: Thursday, October 02, 2008 11:32 AM
Subject: [OSL | CCIE_Voice] GK calls failed - Receive wrong digit fromPSTN-WAN

I need help,

When I try to call BR2 via GK, I receive garbage of digit on my E2

Example:

I dial 3001- prefix 011331328 and the call go through my HQ-RTR and PSTN-WAN

I do
-debug vpm signal

I receive 312483001

-debug voice ccapi inout

I receive 331 324 8300

But for BR2 I'm suppose to receive 3313283001

Here the configuration of my HQ-RTR

Gatekeeper
zone local HQ-RTR ipexpert.com 172.28.100.1
zone remote PSTN-WAN ipexpert.com 10.28.200.2 1719
zone prefix PSTN-WAN 011*
no shutdown

Thanks


David Corbeil
Consultant en technologie | Technology Consultant
Tel. 514-215-2490 | Fax. 514-748-5333
Membre de l'équipe TELUS

Reply via email to