Not this time I prefix 011331322 because I now on pod 12
And I receive that "Called Number=33132433313223001" So I receive this extra digit "3313243" So past Thursday a tech call me from IP EXPERT to change Translation in PSTN-WAN to fix the problem. Thanks David Corbeil Consultant en technologie | Technology Consultant Tel. 514-215-2490 | Fax. 514-748-5333 Membre de l'équipe TELUS ________________________________ From: Michael Shavrov [mailto:[EMAIL PROTECTED] Sent: Sunday, October 05, 2008 11:24 AM To: David Corbeil Cc: ccie_voice@onlinestudylist.com Subject: Re: [OSL | CCIE_Voice] GK calls failed - Receive wrong digit fromPSTN-WAN Hi David, First of all, you should carefully check your "voice translation-rule" and your "num-exp". Looks like you have some runaway translations, which insert and/or drop digits into your dialing string. When you look really close to your digits, you will notice that they are not that much "garbage": 1. You dial "3001" with the prefix "001331328", which results as: 011-331-328-3001 (by the way, what is the tech-prefix???) 2. Your "debug vpm signal" shows similar digits with some "missing and some "extra" digits within: [missing 3] 31 [missing 3] 2 [extra 4] 8-3001 3. And your "debug voice ccapi inout" shows: 331 324 8300 (another representation: 331-32 [extra 4] 8-300 [missing 1]) Good luck, Mike ---- http://cciev.headsetadapter.com ----- Original Message ----- From: David Corbeil<mailto:[EMAIL PROTECTED]> To: 'ccie_voice@onlinestudylist.com'<mailto:'ccie_voice@onlinestudylist.com'> Sent: Thursday, October 02, 2008 11:32 AM Subject: [OSL | CCIE_Voice] GK calls failed - Receive wrong digit fromPSTN-WAN I need help, When I try to call BR2 via GK, I receive garbage of digit on my E2 Example: I dial 3001- prefix 011331328 and the call go through my HQ-RTR and PSTN-WAN I do -debug vpm signal I receive 312483001 -debug voice ccapi inout I receive 331 324 8300 But for BR2 I'm suppose to receive 3313283001 Here the configuration of my HQ-RTR Gatekeeper zone local HQ-RTR ipexpert.com 172.28.100.1 zone remote PSTN-WAN ipexpert.com 10.28.200.2 1719 zone prefix PSTN-WAN 011* no shutdown Thanks David Corbeil Consultant en technologie | Technology Consultant Tel. 514-215-2490 | Fax. 514-748-5333 Membre de l'équipe TELUS