couple things jump out
1. do you have any dial-peers configured? No dial-peers no registration
2. allow-coonectionc are they configured
allow-connection sip -sip
h323 to sip etc
Respectfully Charles George
From: juliana...@hotmail.com
To: ccie_voice@onlinestudylist.com
Date: Fri, 7 Aug 2009 20:59:35 +0000
Subject: [OSL | CCIE_Voice] V2 lab 1 - ipipgw issue
I have a weird issue regarding ipipgw. I configure it as h323 gateway, but it
registers to gatekeeper as voip-gw. Then when there is a call from HQ to BR2,
gatekeeper complains that there is no ipipgw and the call fails.
I know once the ipipgw registers to gatekeeper as h323-gw, the call will pass
through. I succeeded once, after several hours' issuing shut/no shut
gatekeeper, no gateway/gateway, and trying other things. Then all of sudden it
registered as h323-gw, I tried to figure out the reason by changing back what I
had modified, however ipipgw registered alway as h323-gw, could't find out the
reason.
So my question are:
1. how to force ipipgw registers to gatekeeper as h323-gw/
2. Why it registers as voip-gw even though the configuration is for h323
3. What's the difference between h323-gw and voip-gw
Just wondering whether some has the same issue?
Thanks in advance.
Here's the configuration:
int lo0
h323-gateway voip interface
h323-gateway voip id VIA ipaddr 172.30.16.16 1719
h323-gateway voip h323-id rtr
gatekeeper
zone local VIA ipexpert.com 172.30.16.16
zone local CUM ipexpert.com
zone local CUME ipexpert.com outvia VIA
no shutdown
Router#sh gatek en
GATEKEEPER ENDPOINT REGISTRATION
================================
CallSignalAddr Port RASSignalAddr Port Zone Name Type Flags
--------------- ----- --------------- ----- --------- ---- -----
172.30.16.16 1720 172.30.16.16 56256 VIA VOIP-GW
H323-ID: rtr
Voice Capacity Max.= Avail.= Current.= 0
172.30.16.18 1820 172.30.16.18 64266 CUME H323-GW
H323-ID: BR2-RTR
Voice Capacity Max.= Avail.= Current.= 0
172.30.16.19 1720 172.30.16.19 34001 CUM VOIP-GW
H323-ID: gk-trunk_1
Voice Capacity Max.= Avail.= Current.= 0
Total number of active registrations = 3
See all the ways you can stay connected to friends and family
_________________________________________________________________
Get free photo software from Windows Live
http://www.windowslive.com/online/photos?ocid=PID23393::T:WLMTAGL:ON:WL:en-US:SI_PH_software:082009
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit
www.ipexpert.com