I had a same issue few days ago turned out to be region
mis-configuration. Obviously CTI port/RP needs to be registered as well.
Press the message button on br2 phone and then press "?" to see what
codec it's trying to negotiate.
From: [email protected]
[mailto:[email protected]] On Behalf Of Michael
Ciarfello
Sent: Tuesday, 20 October 2009 7:30 AM
To: Kevin Porter; [email protected]
Subject: Re: [OSL | CCIE_Voice] Volume 2, Lab 3, Question 7.2
CTI ports and CTI RP need to show registered.
You need to reboot CUE whenever you make a CTI change.
If you can import the users, the JTAPI user is good. Isn't there
another menu where you can verify Callmanager? Something under the
system menu or something?
From: [email protected]
[mailto:[email protected]] On Behalf Of Kevin
Porter
Sent: Monday, October 19, 2009 4:29 PM
To: [email protected]
Subject: [OSL | CCIE_Voice] Volume 2, Lab 3, Question 7.2
All,
Having a horrible time getting CUE to work with the CUCM integration.
All I get is fast-busy when hitting the VM button on the BR2 Phones,
fast-busy when dialing the pilot directly from BR2 phones and fast busy
when any calls are sent to VM (either form BR2 phone to Phone or from
BR1/HQ). Finally gave up and used the Proctor Guide and it looks like I
did not miss anything in the configuration, but still No Joy. I am able
to "import " the users from CUCM, so the web admin user should be good,
tried reconfiguring the JTAPI password a couple time, but still can't
get anything but fast-busy...BR2 has a Transcoder registered for calls
across the WAN. I can't recall if the CTI ports be "registered" to CUE
or not? Any tidbits of troubleshooting information would be greatly
appreciated...
Thanks,
Kevin
________________________________
This transmission and any attached files are privileged, confidential or
otherwise the exclusive property of the intended recipient or
Netelligent Corporation. If you are not the intended recipient, any
disclosure, copying, distribution or use of any of the information
contained in or attached to this transmission is strictly prohibited. If
you have received this transmission in error, please contact us
immediately by responding to this message or by telephone (314-392-6900)
and promptly destroy the original transmission and its attachments.
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email
______________________________________________________________________
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit
www.ipexpert.com