Hello,

i willget the output ande send it to you

thanks

On Tue, Nov 24, 2009 at 5:24 AM, Otto Sanchez <o...@ipexpert.com> wrote:

> 1.- Are intl calls the only ones that fail?, which ones succeed?
> 2.- What is your Mobile Voice Access Directory Number (in ucm)?
> 3.- How are you dialling that intl number?,
> 4.- What is your intl route pattern?
> 5.- Send the debug voip dialpeer of the outgoing gw if h323
> 6.- Send the debug isdn q931 of the outgoing gw
> 7.- Send the router config, mva gw and outgoing gw
>
> Please answer ALL the questions,
>  --
> Regards,
>
> Otto Sanchez
> CCIE #25592 (Voice), CCVP,CCSP,CCNP,CCDA,MCSE.
> Sr. Support Engineer - IPexpert, Inc.
> URL: http://www.IPexpert.com <http://www.ipexpert.com/>
>   On Mon, Nov 23, 2009 at 11:34 PM, Omotayo <adefilabi...@gmail.com>wrote:
>
>> Hello,
>> i was able t dial the mobile voice access. i was not able to dial an
>> innternational number after logging it. the call gets to the router but was
>> not ringing on the called phone
>>
>>   On Tue, Nov 24, 2009 at 4:57 AM, Otto Sanchez <o...@ipexpert.com>wrote:
>>
>>> Check that your router outgoing voip dialpeer's destination pattern
>>> matches the mva number and length you defined in the Media Resources->
>>> Mobile Voice Access-> Mobile Voice Access Directory Number, otherwise your
>>> calls will be dropped/disconnected,
>>>
>>> Also, what number are you trying to dial?, is it internal or external?
>>>
>>> Thanks,
>>>
>>>
>>>   On Mon, Nov 23, 2009 at 9:14 PM, Omotayo <adefilabi...@gmail.com>wrote:
>>>
>>>>   Hello,
>>>>
>>>> i have configured Mobile access on the h323 gateway. i am able to
>>>> callin. when  tried to call after logging in. i get the following message 
>>>> on
>>>> debug isdn q931 but the called number never rings
>>>>
>>>> the CSS ( not the reruting CSS) of the remote destination has a
>>>> partition that points to the route pattern that dials out
>>>>
>>>>
>>>> BR2-RTR(config)#
>>>> Nov 24 01:34:32.452: %ISDN-6-CONNECT: Interface Serial0/0/0:1 is now
>>>> connected to 3432143003 N/A
>>>> Nov 24 01:34:32.500: %ISDN-6-CONNECT: Interface Serial0/0/0:0 is now
>>>> connected to 32141891 N/A
>>>> BR2-RTR(config)#
>>>> Nov 24 01:34:55.372: %ISDN-6-DISCONNECT: Interface Serial0/0/0:2
>>>> disconnected from 32141891 , call lasted 28 seconds
>>>> BR2-RTR(config)#
>>>> Nov 24 01:34:55.376: ISDN Se0/0/0:15 Q931: TX -> DISCONNECT pd = 8
>>>> callref = 0x80AD
>>>>         Cause i = 0x8090 - Normal call clearing
>>>> Nov 24 01:34:55.384: ISDN Se0/0/0:15 Q931: RX <- RELEASE pd = 8  callref
>>>> = 0x00AD
>>>> Nov 24 01:34:55.388: ISDN Se0/0/0:15 Q931: TX -> RELEASE_COMP pd = 8
>>>> callref = 0x80AD
>>>> Nov 24 01:34:55.396: ISDN Se0/0/0:15 Q931: RX <- DISCONNECT pd = 8
>>>> callref = 0x8093
>>>>         Cause i = 0x8290 - Normal call clearing
>>>> Nov 24 01:34:55.396: %ISDN-6-DISCONNECT: Interface Serial0/0/0:1
>>>> disconnected from 3432143003 , call lasted 28 seconds
>>>> Nov 24 01:34:55.400: ISDN Se0/0/0:15 Q931: TX -> RELEASE pd = 8  callref
>>>> = 0x0093
>>>> Nov 24 01:34:55.408: %ISDN-6-DISCONNECT: Interface Serial0/0/0:0
>>>> disconnected from 32141891 , call lasted 28 seconds
>>>> Nov 24 01:34:55.408: ISDN Se0/0/0:15 Q931: RX <- RELEASE_COMP pd = 8
>>>> callref = 0x8093
>>>> Nov 24 01:34:55.408: ISDN Se0/0/0:15 Q931: TX -> DISCONNECT pd = 8
>>>> callref = 0x80AB
>>>>         Cause i = 0x8090 - Normal call clearing
>>>> Nov 24 01:34:55.420: ISDN Se
>>>> BR2-RTR(config0/0/0:15 Q931: RX <- RELEASE pd = 8  callref = 0x00AB
>>>> Nov 24 01:34:55.424: ISDN Se0/0/0:15 Q931: TX -> RELEASE_COMP pd = 8
>>>> callref = 0x80AB)#
>>>> BR2-RTR(config)#
>>>>
>>>> Anyone with an idea of what am missing
>>>>
>>>> hanks
>>>>
>>>> _______________________________________________
>>>> For more information regarding industry leading CCIE Lab training,
>>>> please visit www.ipexpert.com
>>>>
>>>>
>>>
>>>
>>> --
>>> Regards,
>>>
>>> Otto Sanchez
>>> CCIE #25592 (Voice), CCVP,CCSP,CCNP,CCDA,MCSE.
>>> Sr. Support Engineer - IPexpert, Inc.
>>> URL: http://www.IPexpert.com <http://www.ipexpert.com/>
>>>
>>
>>
>
>
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to