With the gatekeeper max-calls command - I have the following config to only 
allow one active call to the CM sub and all subsequent calls will route to the 
pub:

 no shutdown
 endpoint resource-threshold
 endpoint max-calls h323id CM-Trunk_2 1
 endpoint max-calls h323id CM-Trunk_1 1000

This works fine for call from CME to CM thru the GK.  But in the CM to CME 
direction one call succeeds and any subsequent calls fail.  It seems CM will 
not re-initiate the call attempt from the pub.  I thought there was a service 
parameter needed in conjunction with the max call command on the GK but I am 
not able to find.  Am I missing a simple service parameter or is something else 
needed?


                                          