No Asher In this case you don't need to bind or unbind your MGCP GW is diff other GK config and if your bind loop back to with H323 GW (GK will always work as H323) that int will act as GK int in the same HQ-Router but Kobel is trying to config as a H323 GW and H323 GK that's why he can't configured two int with H323 command and you don't to bind loop with H323 be default it will as H323 GK and ACF and LCF both contain the ip address of the remote GW and GK info.
Guys Pls correct me if i am wrong .... Thanks Sal On Fri, Jun 4, 2010 at 12:01 PM, Ashar Siddiqui <[email protected]> wrote: > What if it’s an MGCP gateway? > > > > If on an MGCP gateway, I have bind control and bind media to voice vlan IP > address while the gatekeeper is on loopback... > > So to make this work, do I need to remove the bind control and bind media > command? > > > > I am a little confused here.. > > > > *From:* kobel [mailto:[email protected]] > *Sent:* 04 June 2010 16:37 > *To:* Pavan > *Cc:* Ashar Siddiqui; [email protected] > *Subject:* Re: [OSL | CCIE_Voice] vol 2 lab 1: gatekeeper and H.323 GW on > the same router > > > > bingo! indeed, this solved the issue. > > This command obviously binds all H.323 signaling to specific interface > (loopback in my case). So this explains why the incoming calls were > associated with the GK-controlled trunk (GK configured on loopback). After > removing this command, the source address is bound with voice interface IP > address, which is ok. > > Another lesson learned - for calls routed via GK, the SETUP which CUCM > receives contains the source signaling IP address of the GK (despite the > fact it's sent directly by the remote GW). This is why CUCM needs to sent > ARQ to GK. Only ACF contains the signaling IP address of the remote GW. Now > it makes perfect sense, but I've never though about it. > > But still, one thing is not clear for me. What's the difference between: > * h323-gateway voip interface > * h323-gateway voip bind srcaddr 10.225.100.254 > The command reference is not very clear on this. > > Thanks for your input! > > On Fri, Jun 4, 2010 at 5:08 PM, Pavan <[email protected]> wrote: > > > > in your existing config, remove the h323gw bind source interface command > > > > _______________________________________________ > For more information regarding industry leading CCIE Lab training, please > visit www.ipexpert.com > >
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com