Check if the MOH server is a DP with region of G.711 to everywhere.
On Fri, Jun 4, 2010 at 3:30 PM, Ashar Siddiqui <[email protected]> wrote: > > > R2#sh ephone summary > > hairpin_block: > Max 5, Registered 0, Unregistered 0, Deceased 0 High Water Mark 6, Sockets 0 > ephone_send_packet process switched 0 > > > Max Conferences 8 with 0 active (8 allowed) > Skinny Music On Hold Status > Active MOH clients 0 (max 210), Media Clients 0, B-ACD Clients 0 > No MOH file loaded > File play position 0 file type 0 > Play offset 0, Write offset 0,File start 0 end 2147483647 current type 0 > Data at 0, size 0 > RTP ssrc 0 timestamp_offset 0 position 0 reposition 0 > Max process service interval 0 (last 0) > Min interval -1, missed 0 run 0 (us) > moh_process_service counter 0 > Max Media process interval 0 (last 0) run 0 (us) > File system max access time 0 (us) (last 0) with late-reads 0 > 0 clients interrupt service, 0 process level > 0 no-conversion, 0 a-to-mu, 0 mu-to-a > 0 packets serviced at interrupt, 0 at process > > Media Client Tx: 0 Xcode Tx: 0 > > > But when I have put PSTN on-hold, I am getting correct multicast address: > > R2#sh call active voice | inc RemoteMedia > RemoteMediaIPAddress=239.1.1.1 > RemoteMediaPort=16384 > R2# > > > Kevin Damisch wrote: > > Does phone to phone MOH work? What does “show ephone summary | include > type” give you? > > > > From: [email protected] > [mailto:[email protected]] On Behalf Of Ashar Siddiqui > Sent: Friday, June 04, 2010 3:07 PM > To: ccieid1ot > Cc: [email protected] > Subject: Re: [OSL | CCIE_Voice] MOH not working from H323 Gateway > > > > debug moh? > > You mean deb ephone moh.. > > No, there is no output! > > ccieid1ot wrote: > > debug moh. Trace it from there. > > > > On Fri, Jun 4, 2010 at 2:55 PM, Ashar Siddiqui <[email protected]> wrote: > > > > No I am not :) > > > > Like I said, this never happened with me before...config is exactly the > > same... > > > > Shadow of Voice wrote: > > > > you must me missing route under call-manager-fall-back from Voice vlan int > > to loop back 0 int ..... > > > > On Fri, Jun 4, 2010 at 3:41 PM, ccieid1ot <[email protected]> wrote: > > > > Let's see the configs under Call-manager fall-back. Try removing the > > multicast and readding it again. > > > > On Fri, Jun 4, 2010 at 2:38 PM, Ashar Siddiqui <[email protected]> > > wrote: > > > > Hi all, > > > > I am facing a weired scenario at the moment, > > MOH from H323 gateway..it always worked for me but for some reason its > > not > > working at the moment. > > MRG and MRGL has been created, multicast checked, MOH region G711 ..all > > those usuals.. > > > > At the gateway, I have ccm-manager music-on-hold and then under > > call-manager-fallback I have moh and multicast commands..max-ephone, > > max-dn > > etc... > > > > This config use to work, always...now when I am making a PSTN call and > > putting it on HOLD...all I hear is silence.. > > > > This is what I am getting: > > > > R2#sh ccm-manager music-on-hold > > Current active multicast sessions : 1 > > Multicast RTP port Packets Call Codec Incoming > > Address number in/out id Interface > > =================================================================== > > 239.1.1.1 16384 0/0 13 g711ulaw > > R2# > > > > No Interface mentioned under incoming interface..it use to show > > Loopback. > > > > Also deb ephone moh is generating nothing.. > > > > Where I am going wrong? > > > > This is something which has always worked for me... > > > > Thanks. > > > > _______________________________________________ > > For more information regarding industry leading CCIE Lab training, > > please > > visit www.ipexpert.com > > > > > > > > _______________________________________________ > > For more information regarding industry leading CCIE Lab training, please > > visit www.ipexpert.com > > > > > > > > > > > > > > > > ________________________________ > This communication (including any attachments) is intended only for the use > of the individual or entity to which it is addressed, and may contain > information that is privileged, confidential and exempt from disclosure > under applicable law. If you are not the intended recipient, any > dissemination, distribution or copying of this communication is strictly > prohibited. If you have received this communication in error, please notify > Vital Support Systems at 515 334 5700 and delete or destroy all copies and > the original document. > > _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com