Do you mean that CUE is integrated with CUCM (JTAPI) or with CME?

The transcoding should always be done closer to the site that does the
G711 or else the transcoder will fail to serve the purpose of saving
bandwidth across the WAN.

For CME integration, it is should be done at the CME/CUE always.

An scenario where the transcoding could be done local on the CUCM with
JTAPI integration would mean you configure it like this:
IP Phones region is G729 towards CUE Ports
Transcoder could be on HQ or BR2 router, with G711 towards CUE ports.

In this scenario, you could have priority of using the BR2 router
transcoder, and then fallback to HQ transcoder. The latter will not be
optimal as the call will use G711 across the WAN but the call will
work.

On Tue, Jul 6, 2010 at 10:41 AM, Mark Holloway <[email protected]> wrote:
> If calls should complete using G.729 from HQ/BR1 to CUE on BR2 which is 
> G.711u, can the transcoding be configured on the BR2 router locally or does 
> it need to happen via the originating party's transcoding resources in UCM?
>
> _______________________________________________
> For more information regarding industry leading CCIE Lab training, please 
> visit www.ipexpert.com
>



-- 
Randall "da ill" Saborio
CCIE Voice Wannabe #10054675811
(Real number coming this July 2010)
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to