Hi,

  HQ phone calls B phone (in SRST) and is CFNA to VM.
  I see the redirecting number,

Br1#
*Sep 19 02:41:12.813: ISDN Se2/0:15 Q931: Applying typeplan for sw-type 0x12
is
0x0 0x0, Calling num +14082022001
*Sep 19 02:41:12.813: ISDN Se2/0:15 Q931: Applying typeplan for sw-type 0x12
is
0x2 0x1, Called num 14082022220
*Sep 19 02:41:12.813: ISDN Se2/0:15 Q931: TX -> SETUP pd = 8  callref =
0x00AC
        Bearer Capability i = 0x8090A3
                Standard = CCITT
                Transfer Capability = Speech
                Transfer Mode = Circuit
                Transfer Rate = 64 kbit/s
        Channel ID i = 0xA98382
                Exclusive, Channel 2
        Display i = 'HQ ph 1'
        Calling Party Number i =0x0081, '+14082022001'
                Plan:Unknown, Type:Unknown
        Called Party Number i = 0xA1, '14082022220'
                Plan:ISDN, Type:National
        Redirecting Number i = 0x000082, '3001'
                Plan:Unknown, Type:Unknown


HQ#
Sep 19 02:43:46.215: ISDN Se0/1/0:15 Q931: RX <- SETUP pd = 8  callref =
0x00BA
        Bearer Capability i = 0x8090A3
                Standard = CCITT
                Transfer Capability = Speech
                Transfer Mode = Circuit
                Transfer Rate = 64 kbit/s
        Channel ID i = 0xA98381
                Exclusive, Channel 1
        Display i = 'HQ ph 1'
        Calling Party Number i = 0x0081, '+14082022001'
                Plan:Unknown, Type:Unknown
        Called Party Number i = 0xA1, '4082022220'
                Plan:ISDN, Type:National
        Redirecting Number i = 0x000082, '3001'
                Plan:Unknown, Type:Unknown


But at the Unity Connection, I don't see the redirecting number. What should
I check?

10:58:15, New Call, CalledId=2220,  RedirectingId=,  Origin=16,  Reason=1,
CallGuid=A74121B2012F469DAFA1C2D790B4AB00,  CallerName=HQ ph 1,
LastRedirectingId=,  LastRedirectingReason=1024,
PortDisplayName=ccievoice-1-003,[Origin=Invalid],[Reason=Invalid]
10:58:15, AttemptSignIn
10:58:15, State - AttemptSignIn.cde!Dummy
10:58:15, Event is [NULL]
10:58:15, PHTransfer
10:58:15, State - PHTransfer.cde!LoadInfo
10:58:15, Event is [TrueEvent]
10:58:15, PHGreeting
10:58:15, State - PHGreeting.cde!PlayGreeting
10:58:15, Call answered if needed
10:58:15, Playing greeting for Call Handler:  Opening Greeting
10:58:21, Event is [HangupEvent]
10:58:22, State - PHGreeting.cde!DoHangup
10:58:22, Event is [HangupEvent]
10:58:22, Idle