Yes incoming called-number 1999.. Will work for MWI.

 

From: Mritunjay Kumar [mailto:mjs...@gmail.com] 
Sent: 20 January 2011 13:48
To: Ashar Siddiqui
Cc: ccie_voice@onlinestudylist.com
Subject: Re: [OSL | CCIE_Voice] how to set mwi on/off number in unity
express

 

Hi Ashar ,

thanks for reply.

i had configured same config  and it was not working until i added following
dial-peer 

dial-peer voice 100 voip
codec g711ul
incoming called 199.....
ses pro sip


what i observed through ccsip message that cue dials 1990(1)2000 (2000 is
subs ext)  which works only when it is received by sip voip dial-peer which
has codec g711 setting. i did not find any doc which tell this and was
wondering whether same works without creating any dial-peer ...

any thought ?

Regards,
Mritunjay

On Thu, Jan 20, 2011 at 6:30 PM, Ashar Siddiqui <siddas...@gmail.com> wrote:

You will have to create mwi on and mwi off ephone dn. Let's say:

 

ephone-dn  8

number 1990....

mwi on

!         

!

ephone-dn  9

number 1991....

mwi off

!

!

 

If you want to set MWI on, dial 19902601 and it should turn the light on
(2601 being any ext.)

 

Ash>

From: ccie_voice-boun...@onlinestudylist.com
[mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Mritunjay Kumar
Sent: 20 January 2011 10:25
To: ccie_voice@onlinestudylist.com
Subject: [OSL | CCIE_Voice] how to set mwi on/off number in unity express

 

Hi All,

Need some config help 

Here is my config on CME And unity express and it works perfectly ie mwi on
/off

ephone-dn 1 
 number 4000 // this is ext of subcriber 
mwi sip 

sip-ua 
 mwi-server ipv4:14.160.115.196 unsolicited

in cue 

ccn subsystem sip
 gateway address "14.160.115.195"
 dtmf-relay rtp-nte
 mwi sip sub-notify
 end subsystem


this config works ie mwi on /off works

but i want to set the mwi on / off number to specific number ie 2222/2223

i changed this value in cue 

ccn application ciscomwiapplication aa
 description "ciscomwiapplication"
 enabled
 maxsessions 6
 script "setmwi.aef"
 parameter "CallControlGroupID" "0"
 parameter "strMWI_OFF_DN" "2222"
 parameter "strMWI_ON_DN" "2223"
 end application

but mwi does not use these value (verified in debug ccsip message)

it always uses subscriber ext.

what other things need to be changed ?

Regards,
Mritunjay




 

_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to