no just play around w sip trunk --- On Sun, 3/27/11, mihal caro <mihalc...@gmail.com> wrote:
From: mihal caro <mihalc...@gmail.com> Subject: Re: [OSL | CCIE_Voice] MVA using sip trunk To: "Erwan Erwan" <e_er...@yahoo.com> Cc: ccie_voice@onlinestudylist.com Received: Sunday, March 27, 2011, 6:14 PM hi there I had the same problem SIp trunk MVA is support on CUCM 7.13 . If is for the CCIE lab you need to configure it as H323. regards. On 27 March 2011 07:24, Erwan Erwan <e_er...@yahoo.com> wrote: hi all, I tried to config MVA in HQ site, Scenario ------------- I dial in from PSTN to 5999 (MVA #) it gave me prompt for pin and press "1" to dial any outside number (911) 1. If I use SIP trunk It will gave me error saying (below is the complete "debug ccsip message" "Sent: SIP/2.0 400 Bad Request - 'Malformed/Missing Contact field' " 2. However if I use, H323 GW , call out by MVA to outside (ie :911 ) work fine Question ------------- - wondering any parameter in SIP\ trunk I need to check ? tks in adv Complete debug =================== PSTN-WAN# Mar 27 06:07:26.026: //-1/xxxxxxxxxxxx/SIP/Msg/ccsipDisplayMsg: Sent: SIP/2.0 400 Bad Request - 'Malformed/Missing Contact field' Via: SIP/2.0/TCP 10.10.210.10:5060;branch=z9hG4bK1861aabffa From: <sip:??????5001@10.10.210.10>;tag=ad370c0e-63ed-49fa-adb9-1bd65232089c-20651851 To: <sip:911@10.10.110.4>;tag=1343344-12F6 Call-ID: 7bcce880-d8e1d41e-10-ad20a0a@10.10.210.10 CSeq: 101 INVITE Reason: Q.850;cause=100 Content-Length: 0 _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com