That's why we have the have the option ccm-manager fallback-mgcp for MGCP
gateways. So configure that and either CME SRST or call-manager-fallback.

On 12 April 2011 00:51, Randall Crumm <randall.cr...@flextronics.com> wrote:

> HI
>
> In question 6 BACD, It says BR2 is in WAN outage and needs PSTN IB calls
> directed to BACD. This is an MGCP GW.
>
>
>
> Don’t I have to configure call-manager-fallback,telephony-service ephones,
> ephone-dn’s and IP?
>
> Also don’t you need a IB dial-peer?
>
>
>
> Thanks,
>
>
>
> Best Regards,
>
>
>
> Randall Crumm
>
> Voice and Video Architect
>
> Global Networking & Telecom
>
> *[image: ccvp_voice_sm]*
>
>
>
> [image: logo]
>
>
>
> 1007 Gibraltar Drive
>
> Milpitas, CA  95035
>
>
>
> Direct +1 408.576.7344
>
> VoIP 6666.100.7344
>
>
>
>
>
> *Creating value that increases***
>