Nat Echols wrote:

*** For details on how to be removed from this list visit the ***
*** CCP4 home page http://www.ccp4.ac.uk ***



Thanks to all who replied to my indexing question; I think I have the problem sort of figured out now. Either I get better crystals, or I try refining in a large P21 cell. (Hopefully the former.)

If I'm stuck in P21, I have four molecules in the ASU, which are almost exactly crystallographically related. I've been warned that NCS in these cases risks essentially cross-refining the Rfree set. I've also seen reference to picking an Rfree set carefully to avoid this. I guess picking thin resolution shells was the old way, but I also saw a reference to SFTOOLS doing something more precise and picking specific refletions that would be related by my NCS operators. Or something like that. Can anyone explain this further?


I try to make sure the pseudo-symmetry related reflections have the same freer flag. I do this by indexing and assigning FeeRflags to the highest pseudo symmetry. expanding the data to P1 - that generates n identical copies of the FreeRflag
Then reindex that expanded data into the P21 indexing.
Then add the FreeRfalg only from that reindexed P1 set to your P21 data!
Clear???
Eleanor

begin:vcard
fn:Eleanor  Dodson
n:Dodson;Eleanor 
email;internet:[EMAIL PROTECTED]
tel;work:+44 (0) 1904 328259
tel;fax:+44 (0) 1904 328266
tel;home:+44 (0) 1904 424449
version:2.1
end:vcard

Reply via email to