> Apologies for continuing to top-post here...
> 
> If the cleavage would only remove 28 amino acids from a 500 amino acid
> chain, it could easily be missed by SDS-PAGE, although mass spec would
> catch it.  However, I don't think you can get enough sample from a
> dissolved crystal to run mass spec.

Absolutely, yes you can.


What is the low resolution cut-off on the data used in refinement? A
lack of low-res data (cut off of 6 - 10 A) can cause map errors such as
apparent chain breaks.