If you have phenix installed, you may also try: phenix.cns_as_mtz cns_file.cv
http://www.phenix-online.org/documentation/reflection_file_tools.htm Regards, Debanu. -----Original Message----- From: CCP4 bulletin board [mailto:[EMAIL PROTECTED] On Behalf Of Miller, Mitchell D. Sent: Thursday, July 03, 2008 12:26 PM To: CCP4BB@JISCMAIL.AC.UK Subject: Re: [ccp4bb] Parameter MAXSAVE exceeded You could also try cns2mtz? http://www.ysbl.york.ac.uk/~cowtan/cns2mtz/cns2mtz.html Regards, Mitch -----Original Message----- From: CCP4 bulletin board [mailto:[EMAIL PROTECTED] On Behalf Of Ezra Peisach Sent: Thursday, July 03, 2008 11:28 AM To: CCP4BB@JISCMAIL.AC.UK Subject: Re: [ccp4bb] Parameter MAXSAVE exceeded I do not know off hand what a .cv file is - unless it is a cns/xplor reflection file. Instead of using f2mtz - try sftools. Ezra Jayashankar wrote: > Dear scientists and friends, > > When I try to convert a .cv file to .mtz by f2mtz I got the following > error,what it means ans what should I do to get rid of it. > > ''Parameter MAXSAVE exceeded'' > > -- > S.Jayashankar > Research Student > Institute for Biophysical Chemistry > Hannover Medical School > Germany