Hi Nazia,

you did not say what Rwork and Rfree values are... If, for instance,
Rwork=20% and Rfree=21% then a situation when Rfree stays the same or even
increases and Rwork goes down is totally valid as long as a reasonable
Rfree-Rwork gap is maintained.
The point is that you need to look at three numbers Rwork, Rfree and
Rfree-Rwork, not either one of them.

Pavel


On Mon, Dec 9, 2013 at 10:51 PM, Nazia Nasir Phd2009,ProteinCrystall.Lab <
nazia.nasi...@nii.ac.in> wrote:

> Hi,
>
> I am facing a problem in refining one of my structures. With every
> refinement the Rwork is going down. However, the Rfree is stuck and is
> not going down with refinement. I have already solved the structure
> without the co-factor bound. This structure is with the co-factor
> bound. Can anyone suggest the reason for the Rfree getting stuck?
>
> Thanks
>
> --
> Nazia Nasir
> PhD Scholar
> Protein Crystallography Lab
> National Institute of Immunology
> New Delhi
>

Reply via email to