Yes - but isnt that common practice?
Eleanor

On 2 December 2016 at 18:11, Keller, Jacob <kell...@janelia.hhmi.org> wrote:

> Dear Crystallographers,
>
>
>
> Although it seems common practice to use just one wavelength/sweep for the
> refinement of the final model, wouldn’t it make much better sense to merge
> all wavelengths into one, and refine the final model against that?
> Especially if it’s just one crystal, no? Even if some of the sets are
> collected to lower resolution, they should still improve things. And in
> addition to the benefits of increased multiplicity, the different
> wavelengths should cancel some systematic errors as well. Hmm, I wonder.
>
>
>
> Jacob Keller
>
>
>
> *******************************************
>
> Jacob Pearson Keller, PhD
>
> Research Scientist
>
> HHMI Janelia Research Campus / Looger lab
>
> Phone: (571)209-4000 x3159
>
> Email: kell...@janelia.hhmi.org
>
> *******************************************
>
>
>

Reply via email to