Thank you Tim, I had the same impression. 
I am afraid that our chemists will have to wait a little longer before they 
routinely can get absolute configurations from electron diffraction.

Best Herman

-----Ursprüngliche Nachricht-----
Von: Tim Gruene <tim.gru...@univie.ac.at> 
Gesendet: Montag, 20. Juli 2020 14:21
An: Schreuder, Herman /DE <herman.schreu...@sanofi.com>
Cc: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK>
Betreff: Re: [EXTERNAL] chirality with electron diffraction

EXTERNAL : Real sender is  tim.gru...@univie.ac.at   



Dear Herman,

no, I don't think this is routine, yet! 
First of all, instrument manufacturers need to catch up. What's on the market 
is quite behind what is possible - although, I don't have the instrument I'd 
love to have, but at least the meta data transfer to the image headers only 
works when you work with a native CCD camera (stone age, I know), not with a 
hybrid pixel detector.

Secondly, Lukas Palatinus' software is, as far as I know, not yet compatible 
with the rotation method, i.e. when you use XDS or DIALS or mosflm, etc, you 
cannot use his software for dynamic refinement. I also understand that dynamic 
refinement is quite time consuming. Lukas is working on this, though.

Best wishes,
Tim

On Mon, 20 Jul 2020 10:36:49 +0000
"Schreuder, Herman /DE" <herman.schreu...@sanofi.com> wrote:

> Hi Tim,
> 
> thank you for your reply. The 1998 Schenk paper is "new" to me, I had 
> seen this one:
> https://science.sciencemag.org/content/sci/364/6441/667.full.pdf The 
> background of my question was about the status in practice: Is it 
> possible to routinely determine the absolute configuration of small 
> molecules by electron diffraction, or is it something that in theory 
> can be done, but only difficult in practice?
> 
> Best,
> Herman
> 
> 
> 
> -----Ursprüngliche Nachricht-----
> Von: Tim Gruene <tim.gru...@univie.ac.at>
> Gesendet: Montag, 20. Juli 2020 11:03
> An: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK>; Schreuder, Herman /DE 
> <herman.schreu...@sanofi.com> Betreff: [EXTERNAL] chirality with 
> electron diffraction
> 
> EXTERNAL : Real sender is  tim.gru...@univie.ac.at   
> 
> 
> 
> Dear Herman,
> 
> The absolute configuration can be determined, although very 
> differently from X-ray ccrystallography.
> 
> So far, two different experimental approaches have been published: 
> Ma, Oleynikov, Terasaki (2017), https://doi.org/10.1038/nmat4890
> 
> and Brazda et al (2019), 10.1126/science.aaw2560
> 
> The former is based on imaging, the latter is based on dynamical
> refinement: Jansen, Tang, Zandbergen, Schenk (1998),
> https://doi.org/10.1107/S0108767397010489
> 
> There is a very interesting paper by Burmester and  Schroeder Scanning 
> Microscopy Vol. 11, 1997 (Pages 323-334). According to this paper, the 
> anomalous signal in ED is actually stronger than in X-ray 
> crystallography. As far as I know, this has not been pursued further.
> 
> Best wishes,
> Tim
> 
> P.S.: This is a response to your email to Jessica Bruhns in the thread 
> 'quote source inquiry'. This thread has reached an overflow, so I took 
> the liberty to adjust the subject.
> 
> --
> --
> Tim Gruene
> Head of the Centre for X-ray Structure Analysis Faculty of Chemistry 
> University of Vienna
> 
> Phone: +43-1-4277-70202
> 
> GPG Key ID = A46BEE1A



--
--
Tim Gruene
Head of the Centre for X-ray Structure Analysis Faculty of Chemistry University 
of Vienna

Phone: +43-1-4277-70202

GPG Key ID = A46BEE1A

########################################################################

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list 
hosted by www.jiscmail.ac.uk, terms & conditions are available at 
https://www.jiscmail.ac.uk/policyandsecurity/

Reply via email to