Dear Paul, 

thanks for your comprehensive response in spite of my rather general comment. 
And thanks for listening! I hope you see this as constructive criticism and not 
only as blunt complaining (a national tradition ;) ): 

Instead of a screencast I'd like to give at least a few more details on the 
trouble on my end. 

The problems mainly arise when:

- switching maps e.g. from 2Fo-Fc to Fo-Fc, or omit maps (X-ray restraints ?)
- modelling alternative / low occupancy conformations 
- modelling covalent ligand complexes (atom clashes ?)
- parts of the solution are in either of the maps (maybe map averaging would 
help?)

--> which is practically all I am doing, and the result is often a model next 
to but not inside of the density. I am a long-term practitioner of ctrl-drag, 
but with little help in these cases.   

With respect to sophisticated solution and the "method developers’ intention", 
I would like to answer with some experience from our own serial crystallography 
method development. 

For even distribution of micro-crystal slurries, we developed a 
custom-multichannel pipette adapter, went through different iterations, adapted 
and improved the design added more features optimized parameters and it now 
works nicely as intended. However, users rather like to use a single empty 
pipette-tip and distribute a big puddle of slurry manually. Not half as pretty 
as the solution I intended, but admittedly easier, faster cheaper. Thus, in the 
end the user-perspective won over my intention. 

With respect to pull-atoms restraints, I don't think more visibility is going 
to help the case. The restraints themselves appear to be off (if that’s a 
statement that helps in any way).

I hope this helps a little bit to narrow down the hard-to-describe problem. 

Best, 

Eike

-----Original Message-----
From: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK> on behalf of "Schreuder, 
Herman /DE" <herman.schreu...@sanofi.com>
Reply to: "Schreuder, Herman /DE" <herman.schreu...@sanofi.com>
Date: Friday, 4. September 2020 at 15:02
To: "CCP4BB@JISCMAIL.AC.UK" <CCP4BB@JISCMAIL.AC.UK>
Subject: [ccp4bb] AW: [EXTERNAL] Re: [ccp4bb] AW: Going back to Coot 0.8

    Dear Paul,
    Thank you for your explanation. I will try to adapt my way of working to 
the new coot.
    Best,
    Herman

    -----Ursprüngliche Nachricht-----
    Von: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK> Im Auftrag von Paul Emsley
    Gesendet: Freitag, 4. September 2020 13:58
    An: CCP4BB@JISCMAIL.AC.UK
    Betreff: [EXTERNAL] Re: [ccp4bb] AW: Going back to Coot 0.8

    EXTERNAL : Real sender is  owner-ccp...@jiscmail.ac.uk   



    Dear Frustrated Coot 0.9 Users,

    I'd like to let you know that you I have heard similar reports in the 
recent past (including, as you can see, from EJD). I have taken what I believe 
to be remedial action to address the most pressing issue.

    I think the situation has arisen because Coot users are bringing previous 
experience of using RSR into their use of 0.9. Because the movement of the 
non-dragged atoms in 0.8.x was rather unsophisticated, many people learnt (I 
discovered, rather late in the day) to "flick" the dragged atom with a large 
and fast movement to get over a local energy barrier. (Needless to say, I 
hadn't intended for that to happen, the approved way to make such modifications 
was Ctrl-drag over-dragging.) Applying a large and fast flick to the dragged 
atom in
    0.9 often leads to an undesired result. If one then misses that fact that 
an atom pull restraint is still in effect and goes on to drag on another atom, 
then confusion and frustration ensues.

    For myself, by using eigen-flip and jiggle fit beforehand and then by 
combining pepflip, JED Flip and backrub rotamer during RSR I often don't even 
need to pull on the atoms. By adding in interactive contact dots, I can see 
what it is that's causing Coot to not move the atom to where I'm trying to drag 
it (the NBCs have been re-paramaterized and up-weighted in the 0.9.x rewrite). 
I have, from time to time in the past year, used Coot 0.8.x and to me it now 
feels painfully crippled. RSR in Coot 0.9.x is joyfully expeditious and 
pleasingly animated.

    For now (which is to say, before Coot 0.9.1 is available) I suggest keeping 
an eye out for unsatisfied atom pull restraints, and using the "Clear Pull 
Restraints" at moments of confusion. Also, use less flick and more smoothness 
when dragging atoms. For example, a 180 degree rotation of the ribose from the 
Coot tutorial would be difficult, if not impossible using 0.8.x, but in 0.9.x 
one can pull on the hydrogen atom of the O5' 
    to rotate it in a few seconds. I have added a (rather poor) video of me 
doing just that to my channel (I should make a better video).

    With all that said, I am still listening - I will add a change shortly that 
will make the pull atom restraints more obvious by making them fatter, pinker 
and more opaque. If there are still problems and you could somehow make a 
screencast available to me that illustrates the problem, then I would be very 
interested to view it.

    Regards,

    Paul.


    On 04/09/2020 10:05, Schreuder, Herman /DE wrote:
    > Dear Paul,
    > 
    > Here I fully agree with Eike. With the real space refinement in the 
    > new coot the ligand often goes everywhere, except where it should go. 
    > Changing the Xray weight helps sometimes, but not always. In many 
    > cases I do not real-space refine and leave it to Buster to do the 
refinement. It would be very good if the old behavior could be reinstalled.
    > 
    > Best regards,
    > 
    > Herman
    > 
    > *Von:*CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK> *Im Auftrag von 
    > *Schulz, Eike-Christian
    > *Gesendet:* Freitag, 4. September 2020 10:36
    > *An:* CCP4BB@JISCMAIL.AC.UK
    > *Betreff:* [EXTERNAL] [ccp4bb] Going back to Coot 0.8
    > 
    > *EXTERNAL : *Real sender is owner-ccp...@jiscmail.ac.uk 
    > <mailto:owner-ccp...@jiscmail.ac.uk>
    > 
    > Dear Paul,
    > 
    > I have been working with coot for over 10 years now with little reason to 
complain.
    > 
    > However, in spite of trying for a few months now, I am not getting warm 
with coot 0.9.
    > 
    > I like the new eye-candy, and the more organized menus. But fitting 
    > residues and ligands into ED, has never before been so difficult, and 
    > frankly it annoys me that previously simple tasks have become an 
    > effort. It seems as if coot and I see different minima and we always 
disagree where to put the residue. At the moment all my data are at convenient 
resolutions of 1.7Å or better, so there is little ambiguity on that side.
    > 
    > I am using all default settings, but maybe there is something that needs 
to be changed?
    > 
    >   * Is there a way to go back to the old (0.8-style) fitting functions in 
coot 0.9? If so how?
    >   * If not, which of the last coot versions
    >     
(https://urldefense.proofpoint.com/v2/url?u=https-3A__www2.mrc-2Dlmb.cam.ac.uk_personal_pemsley_coot_binaries_release_&d=DwIDaQ&c=Dbf9zoswcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8oHzZyRHMQu1AQ&m=JMRzXNjcC-4YR8SFJTyrf_aNVcxumHrqFuPyV9QJlUM&s=5NsBSHjvi7V_A6kImjIckNzc50syFHFMZyXcv7xVvNA&e=
    >     
<https://urldefense.proofpoint.com/v2/url?u=https-3A__www2.mrc-2Dlmb.cam.ac.uk_personal_pemsley_coot_binaries_release_&d=DwMGaQ&c=Dbf9zoswcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8oHzZyRHMQu1AQ&m=3AflakQZ5Fz_M9sPnssJL3oU4C-u25224gN5ljs5KwA&s=_vveOeCJ42OXDKFFrxFP_yaBEA0xSQBIGW2RWy8kmAk&e=>)
    >     would you recommend?
    > 
    > With best regards,
    > 
    > Eike
    > 
    > ----------------------------------------------------------------------
    > --------------------------------------
    > 
    > To unsubscribe from the CCP4BB list, click the following link:
    > https://urldefense.proofpoint.com/v2/url?u=https-3A__www.jiscmail.ac.u
    > k_cgi-2Dbin_WA-2DJISC.exe-3FSUBED1-3DCCP4BB-26A-3D1&d=DwIDaQ&c=Dbf9zos
    > wcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8o
    > HzZyRHMQu1AQ&m=JMRzXNjcC-4YR8SFJTyrf_aNVcxumHrqFuPyV9QJlUM&s=eaYXeWi77
    > kgDfJvtGBGRhDVnuYKmGhyagkOCVMZI02I&e=
    > <https://urldefense.proofpoint.com/v2/url?u=https-3A__www.jiscmail.ac.
    > uk_cgi-2Dbin_WA-2DJISC.exe-3FSUBED1-3DCCP4BB-26A-3D1&d=DwMGaQ&c=Dbf9zo
    > swcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8
    > oHzZyRHMQu1AQ&m=3AflakQZ5Fz_M9sPnssJL3oU4C-u25224gN5ljs5KwA&s=75WQhZGY
    > Otd4zWRp-4QbaftNeHjcD7TdnUNJCeafm8o&e=>
    > 
    > 
    > 
    > ----------------------------------------------------------------------
    > --------------------------------------
    > 
    > To unsubscribe from the CCP4BB list, click the following link:
    > https://urldefense.proofpoint.com/v2/url?u=https-3A__www.jiscmail.ac.u
    > k_cgi-2Dbin_WA-2DJISC.exe-3FSUBED1-3DCCP4BB-26A-3D1&d=DwIDaQ&c=Dbf9zos
    > wcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8o
    > HzZyRHMQu1AQ&m=JMRzXNjcC-4YR8SFJTyrf_aNVcxumHrqFuPyV9QJlUM&s=eaYXeWi77
    > kgDfJvtGBGRhDVnuYKmGhyagkOCVMZI02I&e=
    > 

    ########################################################################

    To unsubscribe from the CCP4BB list, click the following link:
    
https://urldefense.proofpoint.com/v2/url?u=https-3A__www.jiscmail.ac.uk_cgi-2Dbin_WA-2DJISC.exe-3FSUBED1-3DCCP4BB-26A-3D1&d=DwIDaQ&c=Dbf9zoswcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8oHzZyRHMQu1AQ&m=JMRzXNjcC-4YR8SFJTyrf_aNVcxumHrqFuPyV9QJlUM&s=eaYXeWi77kgDfJvtGBGRhDVnuYKmGhyagkOCVMZI02I&e=

    This message was issued to members of 
https://urldefense.proofpoint.com/v2/url?u=http-3A__www.jiscmail.ac.uk_CCP4BB&d=DwIDaQ&c=Dbf9zoswcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8oHzZyRHMQu1AQ&m=JMRzXNjcC-4YR8SFJTyrf_aNVcxumHrqFuPyV9QJlUM&s=WObQ0_zD2AkvVrmTBHIt0liSCRENbmeKP7NQJQfORwg&e=,
 a mailing list hosted by 
https://urldefense.proofpoint.com/v2/url?u=http-3A__www.jiscmail.ac.uk&d=DwIDaQ&c=Dbf9zoswcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8oHzZyRHMQu1AQ&m=JMRzXNjcC-4YR8SFJTyrf_aNVcxumHrqFuPyV9QJlUM&s=MrY51xu69NDzoho1ql-Qe0SkcNY8eTjK5OyjAsr5os4&e=,
 terms & conditions are available at 
https://urldefense.proofpoint.com/v2/url?u=https-3A__www.jiscmail.ac.uk_policyandsecurity_&d=DwIDaQ&c=Dbf9zoswcQ-CRvvI7VX5j3HvibIuT3ZiarcKl5qtMPo&r=HK-CY_tL8CLLA93vdywyu3qI70R4H8oHzZyRHMQu1AQ&m=JMRzXNjcC-4YR8SFJTyrf_aNVcxumHrqFuPyV9QJlUM&s=5tczq6xBwaqHxiS03OK4nvGKnbHGHUF6V61owlsnfNg&e=

    ########################################################################

    To unsubscribe from the CCP4BB list, click the following link:
    https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

    This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing 
list hosted by www.jiscmail.ac.uk, terms & conditions are available at 
https://www.jiscmail.ac.uk/policyandsecurity/


########################################################################

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list 
hosted by www.jiscmail.ac.uk, terms & conditions are available at 
https://www.jiscmail.ac.uk/policyandsecurity/

Reply via email to