Hey Dr Afshan, You can also check the tab menu: Measure>Go to Atoms. There you can enter the residue number. The particular residue will be selected, and centred. Thereafter go to the Measure tab, and click residue info. A dialogue box will pop open, and there you may edit the values. I hope this will save some time.
BTW, there is a separate listserv for Coot, where coot specialists may suggest another route to solve the issue. Best wishes -Z Zaigham M Khan, PhD Associate Scientist Icahn School of Medicine at Mount Sinai Department of Oncological Sciences 1470 Madison Avenue New York United States On Tue, Jul 27, 2021 at 10:21 AM Afshan Begum < 000001d12a434d1a-dmarc-requ...@jiscmail.ac.uk> wrote: > Hi Experts, > > I have a problem to see the residue information on COOT if I click on > residue info and place the curser their its just blink and disappear as I > want to reduce some occupancy manually and it did not work but for water > and the other stuff its work completely fine but not for the amino acid > residue . > > Could you people help me to do so. > > I am working on MAC system > > Would be thankful to you. > > Best > A.B > > > > > ------------------------------ > > To unsubscribe from the CCP4BB list, click the following link: > https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1 > ######################################################################## To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/