Glen Slick wrote: > I just acquired a KA640 VAX in a BA215 (thanks Josh) which has one > working RF30 and one dead RF30 with failure code 300B(X). I don't have > copies of any manuals which list the error codes. I just figure at > this point that the drive is dead and there is nothing that can be > done to try to fix it.
Ive "fixed" a dead RF31, but the error was A00something. Is thedisk spinning up? Is the head assembly "ratteling" after the spin up? > > The working 150MB RF30 is too small for a useful VMS system although > it would be a decent size if I set up the system as a PDP-11 with an > M7554-PB KDJ11-SB CPU instead of the VAX KA640. Hmm... does the KDJ11-SB support DSSI disks? Don't know... > > For VMS use I would either set up this system with a CMD Q-Bus SCSI > controller, or use an HSD10 in a BA350 to connect SCSI disks to the > DSSI controller. Don't have an HSD10 and it seems that none is available to a fair price in Europe. > > >>>SET HOST/DUP/DSSI 2 > Starting DUP server... > Copyright © 1988 Digital Equipment Corporation > DRVEXR V1.1 D 5-MAY-1989 13:18:42 > DRVTST V1.1 D 5-MAY-1989 13:18:42 > HISTRY V1.0 D 5-MAY-1989 13:18:42 > ERASE V1.3 D 5-MAY-1989 13:18:42 > PARAMS V1.2 D 5-MAY-1989 13:18:42 > DIRECT V1.0 D 5-MAY-1989 13:18:42 > End of directory > > Task Name? PARAMS > Copyright © 1988 Digital Equipment Corporation > > PARAMS> STATUS > > Configuration: > Node R3Q0UA is an RF30 controller > Software RFX V103 built on 5-MAY-1989 13:18:42 > Electronics module name is ZG95105350 > Unit is inoperative, error code 300B(X) > Last known unit failure code 300B(X) > In 100000 power-on hours, power has cycled 216 times > System time is 5-MAY-1989 13:21:44 Exactly 100000 hours? My RF73 has the error 3304(X)...it where really interesting what this means. Regards, Holm -- Technik Service u. Handel Tiffe, www.tsht.de, Holm Tiffe, Freiberger Straße 42, 09600 Oberschöna, USt-Id: DE253710583 www.tsht.de, i...@tsht.de, Fax +49 3731 74200, Mobil: 0172 8790 741