Hello All,
Following a discussion on resurrecting a PDP 11/45 I have started looking at the regulator bricks in the PSU. I have started with a H744. I reformed the three big capacitors, although they seemed to be fine as they charged up from my DC bench PSU and then had zero leakage so I didn't reform them for very long. I then moved on to powering the whole unit from my DC bench PSU and it seemed to run fine. I am using a panel mount 1R resistor, so drawing 5A of the rated 25A. It drew just under 2A from the PSU which was set at 20V. I didn't run it for very long as I wasn't sure how hot to allow the load to get. Is there any sense in measuring ripple when powering this from DC? There does seem to be some ripple: https://rjarratt.files.wordpress.com/2021/12/h744-ripple.png hard to say if that is OK? Also, the indicator light does not work (as expected). I have seen the suggestion to replace it with a CM7381. It looks like these can be sourced <https://www.mouser.co.uk/ProductDetail/?qs=N8%2Bk0S5zvCZ7dMEMH2XU9Q%3D%3D> with relative ease, but I wondered if there might be a better LED-based longer term solution? I was also advised that OL-6003BP is good for the 15V regulators, but these seem to be hard to find, any suggestions there? Thanks Rob